Herunterladen Diese Seite drucken

Balluff BIS U-830-4-011-H Serie Kurzanleitung Seite 4

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
BIS U-830-4-011-H-_
Mobile RFID devices – UHF write/read module
About this guide
This guide provides all the information required for the UHF
write/read module.
It applies to the following models:
BIS U-830-4-011-H-0
Ordering code: BIS01FY
UHF write/read module EU
BIS U-830-4-011-H-1
Ordering code: BIS01FZ
UHF write/read module US (USA/Canada)
Intended use
UHF RFID tags can be read with the UHF write/read
module. The UHF write/read module is solely intended for
use with the BIS V-830-3-011-B-00_basic devices.
The UHF write/read module is available in country-specific
versions with different frequency bands and may only be
operated in the specified regions:
BIS U-830-4-011-H-0
UHF write/read module EU
Frequency range: 865.7...867.5 MHz
BIS U-830-4-011-H-1
UHF write/read module US (USA/Canada)
Frequency range: 902.75...927.25 MHz
Max. permissible transmission power in frequency band:
UHF-RFID 500 mW.
Proper function according to the information in the
technical data is only guaranteed if the product is used
solely as described in the user's guide and the associated
documents as well as in compliance with the technical
specifications and requirements and only with a suitable
original Balluff accessory.
Otherwise, it is deemed non-intended use. Non-intended
use is not permitted and will result in the loss of warranty
and liability claims against the manufacturer.
Reasonably foreseeable misuse
The product is not intended for the following applications
and areas and may not be used there:
In safety-oriented applications in which personal safety
depends on the device function
In explosive atmospheres
In the food contact area
Other applicable documents
A comprehensive user's guide and additional information
about this product can be found at www.balluff.com on
the product page.
1
english
Safety notes
Activities such as installation, connection and startup
may only be carried out by qualified personnel.
Qualified personnel are persons whose technical
training, knowledge and experience as well as knowledge
of the relevant regulations allows him to assess the work
assigned to him, recognize possible hazards and take
appropriate safety measures.
The operator is responsible for ensuring that local safety
regulations are observed.
In particular, the operator must take steps to ensure that a
defect in the product will not result in hazards to persons
or equipment.
The product must not be opened, modified or changed. If
defects and unresolvable faults occur in the product, take
it out of service and secure against unauthorized use.
This is a Class A device (EN55032). This device may cause
radio interference in the living area. In this case the
operator may be requested to implement appropriate
measures.
Only original Balluff power supply units may be used for
the operation of the module. The use of unauthorized
components may lead to the destruction of the module or
the basic devices. Do not use the module with an external
device.
The module cannot be installed in the vicinity of heat
sources (e.g. fan heaters) and exposed to direct sunlight,
excessive dust sources or vibrations. Observe ambient
conditions:
Operating temperature: −20...+50 °C
Storage temperature: −20...+60 °C
In order to avoid overheating, the module cannot be
covered during operation.
Before use check the contacts of the module as well as
the contacts of any connectors for dirt and clean if
necessary. Check the module and any connection cables
for damage. Damaged parts must be replaced.