EN
"Mode" button
Used to switch between modes. The selected mode is always indicated by the LED
next to the button.
SMART mode
Air dehumidification mode. The default mode setting is 55 % of humidity in the
room. This value cannot be changed.
FAN mode
Fan mode. The appliance does not dehumidify the air.
LOW mode
Dehumidification at low power of the appliance. The set % of humidity can be
changed by pressing the up or down arrows.
HIGH mode
Dehumidification at high power of the appliance. The set % of humidity can be
changed by pressing the up or down arrows.
If you hold down the "Mode" button for 5 seconds, the dehumidifier will beep
3 times, indicating that it is ready in pairing mode for pairing with the Concept
Home application.
Humidity setting
The buttons are used to save the desired humidity setting in LOW/HIGH mode. The
desired humidity can be set between 40% - 85%. When the desired humidity is set
to 35%, the dehumidifier will dehumidify until the water tank is full - this setting is
suitable for the continuous drainage function.
Humidity indication setting
If the humidity indication setting is active, the circular LED indicator on the front
of the dehumidifier lights up. Depending on the humidity in the room, the LED
indicator will change its colour.
Red - if the humidity is high, RH > 70 %
Green - if the humidity is satisfactory, 70 % ≥ RH ≥ 60 %
Blue - if the humidity is too low, RH < 60 %
Flap rotation
You can set the flap in three ways. You can either set it to an angle of 45 °, 90 °, or
you can set it to oscillate.
UV lamp
Press the "UV" button to turn on the UV lamp function, the LED indicator next to
the button lights up. Press again to turn off the UV lamp, the LED goes out.
68
Note:
When the humidity level drops by 2 % below the desired value. The dehumidifier interrupts its operation. However,
the ventilator will still run for 5 minutes to cool the dehumidification unit. Then it interrupts its operation. After 30
minutes, the dehumidifier checks whether the humidity has risen and, if so, resumes operation. If the humidity is still
less or equal to the desired value, the dehumidifier will wait another 30 minutes.
WARNING:
• The efficiency of the unit is influenced by the air quality in the room of operation. To get the best results when
dehumidifying, do not open and close the windows and doors too often.
• Use the dehumidifier in the designated operation temperature to ensure proper functionality of the dehumidifier.
For safety reasons, dehumidification automatically stops and the fan function is launched instead if the ambient
temperature rises above 36 °C.
• When putting the unit in operation, the circulation of the coolant inside the appliance may produce noises. As the
circulation stabilizes, the noise level decreases.
• After switching off the dehumidifier, do not switch it on for at least 5 minutes. This prevents damage to the
compressor.
• For example, if there is a power failure, the compressor will not turn on immediately after the appliance turns on.
For safety reasons, it does not switch on until 3 minutes later.
• The appliance is intended for indoor use.
• Do not place the dehumidifier opposite radiators or other heat sources.

CLEANING AND MAINTENANCE

• To prevent electric shock, never connect or disconnect the plug with wet hands
• Prior to cleaning or maintenance, first switch the appliance off and disconnect it from the mains.
• Do not remove the float lever from the water tank.
• To prevent device malfunctions or excessive noises, keep the unit in the upright position.
• Wipe the body of the appliance with a soft, dry cloth.
• Use a soft, moist (well wringed out) cloth to remove larger dirt deposits. Never use a damp cloth to clean the control
panel.
• To avoid any deformation or cracking, do not use gasoline, thinner or other liquid detergents.
• Chemicals can cause colour changes of the surface of the appliance.
OV2016 | OV2116
OV2016 | OV2116
Timer
Press the button to set the timer function. If the timer is active, the LED next to the
timer button is lit. Before setting the timer, make sure that it is not already set (LED
must be off). The timer has the following functions:
Shut-down timing
If the appliance is switched on and set according to your requirements, press the
"Timer" button. Use the up/down control buttons to set the time for which the
appliance should run (1-24 hours).
Switch-on timing
If the appliance is in standby mode, you can set the switch-on timer. Press the
"Timer" button and use the up/down buttons to select the time in which you want
the appliance to switch on (1-24 hours).
Ioniser
Press the "Plasma Ioniser" button to turn on the Ioniser function to remove
bacteria, the LED indicator next to the button will light up. Press again to turn off
the Ioniser, the LED goes out.