Herunterladen Inhalt Inhalt Diese Seite drucken

Siemens SIMATIC NET SCALANCE PSP9230PoE Kompaktmontageanleitung Seite 21

Industrial ethernet switches spannungsversorgung
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
5
Connecting
WARNING
Danger to life from line voltage 100 to 240 V AC / 110 to 250 V DC
Contact with live parts can result in death or serious injury. Note the following information to prevent contact with live
parts:
Connecting and disconnecting may only be performed by an electrical specialist in accordance with IEC 62368-1.
Before installation work is started, the main switch of the system must be switched off and secured against being
switched on again.
Power supply cables may only be connected or disconnected in the de-energized state.
NOTICE
No power supply interruption via the connectors
The connectors for input and output are not approved for power supply interruption and cannot be used as disconnectors. A
suitable disconnector for interrupting the power supply should be provided in the end application.
NOTICE
Damage caused by faulty installation
Note the following information to avoid damage due to incorrect installation:
The connection of the power supply 100 ... 240 V AC / 110 - 250 V DC must be designed according to IEC 60364 and EN
50178.
Observe the relevant country-specific regulations during installation.
Note
For the connection between a SCALANCE PSP9230PoE and a SCALANCE XP-200, there are preassembled cables available in
different lengths. You can find more information in the section "Accessories".
5.1
Connect the power supply of the SCALANCE PSP9230PoE
Overview
The connectors and LEDs of the SCALANCE PSP9230PoE are located on the bottom of the unit:
54 V DC output
24 V DC output
Green LED "L"
Orange LED "OVLD"
Red LED "F"
100-240 V AC / 110-
250 V DC input
-
Power supply of the SCALANCE PSP9230PoE
A5E51309689-AA, 02/2023
Output voltage 54 V DC, M12 socket (L-coded)
Output voltage 24 V DC, M12 socket (L-coded)
Lit when the power supply is ready for operation.
Lit when the power supply is operating in overload. In this case, check the configuration.
Lit when a fault/error has occurred, e.g. a short-circuit at the output. In this case, check
the configuration.
Input voltage100 to 240 V AC / 110 to 250 V DC, M12 plug (S-coded)
Pressure equalizing membrane for degree of protection IP65.
English
21

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis