2. IMPORTANT INFORMATION

The installation and operation information given here is of
general nature. National and European standards, local and
building regulations as well as fire prevention laws must be
observed during the operation of the stove.
General safety instructions for the
operation of your stove
Thoroughly read the entire manual before starting up
your stove and observe the caution notices.
The manufacturer states: Multiple use of the chimney is
possible, provided that local regulations permit such an
installation.
Your heating unit may not be moved without approved
means of transport with sufficient load-bearing capacity.
Your heating unit is not suitable to be used as a stand or
as a ladder.
Please keep in mind that your stove's
surface heats up considerably during
operation. We therefore recommend
wearing a safety mitten when operating
your stove
Attention – stove varnish is no rust prevention!
Make your children aware of this particular danger and
keep them at a distance from the heating unit whenever it
is in operation.
Only burn approved fuels and materials listed in the
chapter "Clean Burning".
The burning or placing of flammable or explosive
materials, such as empty spray cans and such like into the
firebox as well as the storage of such materials in the
immediate vicinity of your heating unit is strictly forbidden
due the danger of explosion.
Do not wear loose or flammable clothing when adding
fuel to the fire.
Placing non-heat-resistant objects on the heating unit
or in the vicinity of the heating unit is forbidden.
Do not lay laundry onto the stove for drying. Laundry
hung up to dry must be kept at a safe distance from the
stove because of the danger of fire.
The woodstove KOKO 2.0 is not suitable for long term
heating.
During the operation of your heating unit it is forbidden
to use flammable or explosive materials in the same or an
adjacent room to the one in which your heating unit is
located
The appliance must be operated with the stove door
closed.
The stove door and all fittings for adjusting the stove
must be closed, if the appliance is out of use.
Setting up your stove
Required safety distances
see name plate - in Fig. 2)
a >
1200 mm
b >
540 mm
c >
180 mm
(a – toward the front in the radiated area)
(b – to the side)
(c – to the back)
Make sure that the room in which the stove is set up has at
least one door or window into the outside or is directly
adjacent to such a room. Other fireplaces and extractor
hoods must not be operated in the same room as the stove.
Floor load capacity
Make sure that the load capacity of the supporting
construction is sufficient to carry the weight of the entire
unit, before the heating unit is installed.