SERVICE
IMPORTANT! To eliminate the risk of electric shock in the event of a fault, the generator must be grounded. Connect the ground
terminal (A) to an external ground using a suitable wire.

CHECK BEFORE USE

Check the engine oil level
ATTENTION! Test the generator on a flat surface with the engine off.
1.
Remove the cover screw and remove the cover on the left side.
2.
Remove the oil filler cap (A) and wipe the dipstick with a clean cloth.
Check the oil level by inserting the dipstick into the oil refill hole (B) without screwing it in.
3.
If the oil level is below the end of the dipstick, top up with the recommended oil to the top of the oil filler
4.
hole (C).