English
► Align the docking station so that the following
conditions have been met:
– The docking station has been positioned on
a level surface.
– The opening of the docking station is facing
forward toward the mowing area.
– The docking station has been aligned hori‐
zontally and is not tilted to the side, the front
or the rear.
– The base plate does not sag and lies flat on
the ground.
7.2
Positioning the docking station
The correct position of the docking station
depends on the planned location and its sur‐
roundings.
► Select the location and set up the docking sta‐
tion as described.
Positioning the docking station within the mowing
area
The docking station is at the edge of the mowing
area by a wall and the guide wire (1) can be
routed for a =2 m in a straight line from the dock‐
ing station to the mowing area.
The docking station is at the edge of the mowing
area. The adjacent area is navigable and the
guide wire (1) can be routed for a =2 m in a
straight line from the docking station to the mow‐
ing area.
62
a
90°
1
a
90°
1
7 Positioning the docking station
The docking station is partially in a bed and parti‐
ally on the mowing area and the guide wire (1)
can be routed for a =2 m in a straight line from
the docking station to the mowing area.
The docking station is partially in the mowing
area and the guide wire (1) can be routed for
a =2 m in a straight line from the docking station
to the mowing area.
► Preparing the docking station,
► Setting up the docking station in a mowing
area,
7.4.
Setting up the docking station outside the mow‐
ing area
a
The docking station is outside the mowing area.
The minimum lateral distance toward adjacent
areas must be at least a = 15 cm.
The minimum distance between the front edge of
the docking station and the mowing area must be
at least b = 2 m.
With this variant, it is mandatory to define a start‐
ing point (1) within the mowing area at the con‐
clusion of commissioning. The robot mower then
starts mowing from this point and not directly
a
90°
1
a
90°
1
7.3.
a
b
1
0458-012-9601-A