Herunterladen Inhalt Inhalt Diese Seite drucken

Tecmate OPTIMATE 7 TM260 Anwendungsvorschriften Seite 6

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 23
STEP 1
Voltage
LED #1b => 24V
Selection
1.
Confirms AC power
Disconnect
supply to the charger
battery.
2.
Select
- Lights together with
1 2 V
charge
LED #1a or #1b when
voltage.
1 a
3.
voltage is selected.
Wait until
LEDs #3,
#4, #5, #6,
#7 & #8
flash twice,
confirming
selection is
in memory.
4.
Reconnect
battery.
NOTE:
Selection
remains
even if AC
power is
lost.
STEP 2
flashing ON/OFF
Protection
12V
14.4V
1a
14.7V
1a
2
15.0V
1a
2
24V
12V
1a
28.8V
1b
1b
2
29.4V
12V
1b 2
24V
STEP 3
Immediately following connection to a battery there may be a 1-2 second delay before
30.0V
1b 2
charging progresses, during which time battery State Of Charge and ambient temperature is
Preparing
measured to determine charge requirement and duration of the State Of Health test in STEP 7.
to charge
STEP 4
SAVE
State of
charge:
less than
50%
12V / 24V
4
LED #1a => 12V
Changing voltage selection: Push and release the pushbutton switch.
1a
3
The mode selection changes when the button is released. SAVE (#3),
CHARGE (#4), OPTIMIZE(#5) and TEST (#6,7, 8) LEDs flash twice to
confirm selection is in memory, confirming your battery can now be
12V
LED #1a / 1b :
4
connected.
LED #2 =>
5
24V lead-acid batteries.
LED #2 =>
2 4 V
LED #2 OFF: 14.4V / 28.8V (2.4V / cell) - the standard charging
voltage suitable and safest for all lead-acid battery types.
2
1 b
TIP: If you are not sure of your battery's charging requirements, choose
a higher charge
this mode to avoid overcharging the battery.
LED #2 ON: 14.7V / 29.4V (2.45V / cell) - higher charging voltage
suitable only for specific sealed AGM (absorbed glass mat) flat plate or
spiral cell batteries.
12V
LED #2 flashing: 15.0V / 30.0V (2.5V / cell) - highest charging voltage
14.4V
1a
suitable only for specific maintenance free lead-calcium Ca/Ca batteries
with built in hydrometer indicator 'eye', OR for periodic reconditioning
14.7V
1a
charge of STD wet-cell and Ca/Ca deep cycle batteries.
2
15.0V
1a
IMPORTANT: Selecting 14.7V or 15.0V (for 12V batteries) or 29.4V or
2
30.0V (for 24V batteries) elevates charge voltage in STEP 5 & 6. Confirm
24V
battery charge voltage requirement before selecting a higher charge
voltage. Incorrect selection can lead to overcharging and electrolyte loss
28.8V
through gassing and can cause permanent damage.
1b
29.4V
Proceeding to charge: If the battery's voltage matches the voltage
1b 2
selection the charge mode automatically activates and proceeds to
30.0V
STEP 3. If it does not proceed, see STEP 2.
1b 2
LED #1a / #1b
REVERSE POLARITY / incorrect battery connection (LED #1a and
#1b flashing together) : The charger is electronically protected so no
damage will result, and the output will remain disabled until the
connections are corrected.
VOLTAGE SAFETY CHECK:
12V (#1a) flashing: a battery with voltage exceeding 18V is connected
/ battery may be 24V.
24V (#1b) flashing: a battery with voltage below 18V is connected;
battery may be 12V or it may be a deep discharged 24V battery.
Action: Physically check battery. If nominal voltage is 12V, disconnect
24V
battery and select 12V.
7
If nominal voltage is 24V, push and hold pushbutton switch. After 3
24V
12V
8
seconds program will proceed to STEP 3.
5
4
LED #3 : RED
3
A recondition charge is applied; current is delivered in pulses to prepare
the battery to accept normal charge and increase state of charge above
50%.
1b
2
24V
: There are 3 different charge voltages for 12V /
5
4
8
7
3
6
12V / 24V
Ca/Ca
12V
24V
24V
12V
24-7
24-7
6
The SAVE mode engages if the battery state of charge was less
than 50% or the battery was diagnosed as sulphated.
Charge time: Minimum 15 minutes, maximum 2 hours.
24-7
24-7
6
7
8
2 4 - 7
2 4 - 7

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis