Menu level Parameterization level
Limit value /Limits, LI-2:
LI-2
For both limit values, two different values can be
parameterized. With this, the parameters for each limit value
are called up one after the other.
Hysteresis for limit values, HY-2:
HY-2
For both limit values, a hysteresis function exists that reacts
according to the functional principle (operating
current/quiescent current).
Function if display falls below/exceeds limit value, FU-2:
Fu-2
To indicate if the value falls below the lower limit value, Louu
can be selected (LOW = lower limit value) and if it goes
above the upper limit value, high can be selected (HIGH =
upper limit value). LOW corresponds to the quiescent current
principle and HIGH to the operating current principle.
24
0
0
0
0
0
0
Louu
HIgH
(Low)