Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Pressure Reducing Valve Type 582 HP High Purity
5.3

Versions with manometer

WARNING!
Leakage at pressure gauge outlet!
Risk of material damage and/or injury due to leakage at the pressure gauge outlet for versions with and without adapter.
The pressure gauge bore is drilled at the factory and fitted with a protective plug. Pressure gauge is shipped separately for transport
protection.
► Make sure that the pressure gauge is mounted before commissioning.
WARNING!
Do not adjust the pressure gauge!
Risk of material damage and/or injury due to modification of pressure gauge! Valid for versions with adapter. Pressure gauge is in-
stalled, preset and tested at the factory.
► Do not make any modifications to the pressure gauge.
► Only turn the adapter.
► Do not damage the seal label.
1.
Valve with protective plug at mano-
meter outlet.
2.
Install O-ring at manometer/adap-
tor.
3.
Remove covering cap and turn the
manometer with/without adaptor
with threaded connection into the
valve base part.
4.
Turn
in
manometer/manometer
with adaptor from contact, at least
360° up to max. 720° (align scale).
Maximum torque 2.5 Nm.