Operating Instructions
► Put the bonnet assembly (top part) onto the
body.
► Fix the body and tighten up to the marking/
old seal sticker +20°.
CAUTION!
Incorrect tool for housing nut!
The use of incompatible tools can damage the
housing nut. Escaping medium can cause per-
sonal injury and damage to property.
► Only open and close the housing nut with a
strap wrench or hook wrench.
► Clearance check between top part and
body.
► Install the valve into the pipeline, see chap-
ter „Installation".
► Setting the working pressure, see chapter
«Setting the working pressure»
► Fix the spindle with Allen wrench and si-
multaneously tighten the locking nut with a
suited tool.
Pressure Reducing Valve Type 582 HP High Purity
DN 10/15
DN 20/25
50Nm
70Nm
DN 10/15
DN 20/25
0.5 mm
0.6 mm
DN 32/40/50
120Nm
DN 32/40/50
0.9 mm
27