Troubleshooting

Problem
Motor not running.
Motor stops immediately
after starting.
Motor runs, but no suction.
Motor runs, but poor
suction.
Motor stops during
operation.
Machine blows dust.
Abnormal sound from
machine.

EC Declaration of Conformity

We hereby assure that DC Tromb H complies with the following regulations and standards:
2006/42/EC, 2014/30/EU, 2014/35/EU, EN 60204-1:2018, EN1822-1:2019.
Dustcontrol AB
Nina Uggowitzer / CEO
2022-01-27
Cause
Power supply not connected.
Incorrect fuse.
Suction hose not connected.
Suction hose perforated.
Blocked filter.
Suction hose too long or narrow.
Hose partially blocked.
Top of machine poorly fitted.
Dust trapped in cyclone.
The pump is rotating in the wrong
direction.
Motor overheated.
Filter loose or damaged.
Peter Söderling / Technical Manager
2022-01-27
DC Tromb H, Art.nr. 9480-N
Action
Connect power supply.
Replace with correct fuse.
Connect hose.
Replace hose.
Clean or replace.
Replace hose.
Reverse or clean hose.
Adjust fitting.
Remove top and clean cyclone.
Let an electrician change the phase.
Make sure the machine is not throttled and
wait for it to cool down (about 30 min).
Check and replace as necessary.
Book service.