Fill the suction hose.
Attaching the pressure hose
Screw the threaded connector (11) into the
pump outlet (3).
Attach the elbow nipple (10) to the connector
and turn the nipple so that it points in the de-
sired direction.
Attach a hose to the elbow nipple. The nipple
can be cut to fit the size of the hose used.
Clear the pressure line (open valves, spray-
ers, etc.).
Filling the garden pump
Before putting your garden pump into
operation, you must fill it with water until it
overflows to achieve full suction power. Do
not operate the pump while it is dry be-
cause this will cause serious damage to
the pump.
Remove the filler screw (2).
Pour water into the opening until the cham-
ber of the pump (8) is full.
Replace the filler screw (2) and tighten it.
Switching the pump on and off
Plug the electric cable into the socket.
Make sure that the pump does not run on a
blocked or closed pressure hose.
Clear the pressure line (open valves, spray-
ers, etc.).
Switch the pump on by pushing the switch
(6) to On.
Switch the pump off by pushing the switch
(6) to Off.
Switching off the system
Switch the system off by unplugging the
electric cable from the socket.

Maintenance and Cleaning

Before beginning any maintenance or
cleaning work, make sure that the garden
pump has been unplugged and take
precautions to ensure that it cannot be
switched on during work!
Cleaning the pump
If you have used your garden pump to pump
chlorine water (swimming pool water) or liquids
which leave a residue, flush your pump out with
clear water after use.
Clearing blockages
If your garden pump should become blocked so
that it does not suction or pump out liquid, re-
move the obstruction as follows:
Remove the suction hose from the pump
inlet (1).
Attach the pressure hose to the water tap
and spray water into the pump chamber until
the blockage is flushed out.
Check to see that the obstruction has been
cleared entirely by switching on the pump for
a short time. Do not let the pump suck air.
If the pump runs trouble-free, put it into ope-
ration as described in the instructions.
Frost protection
Store your pump so that it is protected from frost.
Remember to empty it of any remaining liquid
before storing it by removing the filler screw (9)
and dumping out any water.
Do not dispose of worn-out