BTL5-A/C/E/G _ _ -M _ _ _ _ -P-S32/KA _ _
Micropulse Transducer in a Profile Housing
4
Installation and connection (continued)
4.3

Floating magnets

The following must be observed when installing the
magnet:
To ensure the accuracy of the position measuring
system, the magnet is attached to the moving member
of the machine using non-magnetizable screws
(stainless steel, brass, aluminum).
The moving member must guide the magnet on a track
parallel to the transducer.
Ensure that the distance A between parts made of
magnetizable material and the magnet is at least
10 mm (see Figures 4-4 to 4-8).
Maintain the following values for distance B between
the magnet and transducer and for center offset C (see
Figures 4-4 to 4-8):
Type of magnet
BTL5-P-3800-2
BTL5-P-5500-2
BTL5-P-4500-1
BTL6-A-3800-2
BTL6-A-3801-2
For optimum measurement results, a distance B of 6 to 8 mm is
1)
recommended.
Tab. 4-2:
Distance and offset for floating magnets
A
A
Fig. 4-4: Dimensions and distances with BTL5-P-3800-2 magnet
A
A
Fig. 4-5: Dimensions and distances with BTL5-P-5500-2 magnet
8
english
Distance B
Offset C
0.1 to 4 mm
± 2 mm
5 to 15 mm
± 15 mm
0.1 to 2 mm
± 2 mm
4 to 8 mm
± 2 mm
1)
4 to 8 mm
± 2 mm
1)
C
C
A
A
Fig. 4-6: Dimensions and distances with BTL6-A-3800-2 magnet
A
A
Fig. 4-7: Dimensions and distances with BTL6-A-3801-2 magnet
Plug with
A
A
LED
4
Fig. 4-8: Dimensions and distances with BTL5-P-4500-1
electromagnet (24 V/100 mA)
The measuring range is offset by 4 mm towards
the BTL plug (see Figure 4-8).
C
C
C

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis