6.3.1
Horizontal mirror adjustment
1. Switch on the wheel laser.
Never look directly at the laser source!
2. Loosen the fixing screw of the horizontal adjustment
equipment.
3. Adjust mirror until the laser beam falls back to the
perpendicular line of the projection surface of the
wheel laser.
4. If the mirror is set correctly, again lock the adjustment
equipment with securing screw.
5. Read the value on the scale "H" for the horizontal ad-
justment (see fig. 19).
Bsp: H=2,89
456176/1Rf
Fig. 19:
Reading the horizontal adjustment value
6. Put the determined values in the diagnosis system.
6.3.2
Vertical mirror adjustment
1. place the slit diaphragm directly in front of the wheel
laser on the floor.
456181/4-3 Wn
Fig. 20:
Placing the slotted cover on the rear wheel
2. Loosen the fixing screws of the height adjustable
diaphragm.
3. Adjust the diaphragm, so that the laser beam goes
through the middle of the slit
.
Fig. 21:
Adjusting the slit diaphragm
4. Lock the diaphragm again with the fixing screws.
FIAT AG
Checking/ installation of the ACC sensor | ACC 200 | 27
5. Set the slit diaphragm now to the level of the read
wheel on the floor (see fig. 22).
6. Loosen the fixing screw of the quick action clamp.
7. Adjust the wheel laser, so that the laser beam passes
through the middle of the slit of the diaphragm.
Fig. 22:
Aligning the wheel laser
8. Fix the wheel laser again with the securing screw.
9. Adjusted with the knurled nut the mirror vertically, so
that the laser beam is reflected back as close as possible
to the outlet opening on the projection surface of the
wheel laser.
10. On the scale "V" for the vertical adjustment (see fig. 23).
456176/2Rf
Fig. 23:
Reading the vertical position value
11. Put the determined values in the diagnosis system.
12. Switch off the wheel laser again.
13. Loosen the fixing screw of the quick action clamp.
14. Release the wheel laser from the support of the quick
action clamp.
15. Release the quick action clamp from the left rear
wheel.
16. Pull the clamping lever on the hand grip.
 The clamp unit will be opened
"
Latch the installation equipment lightly to the rear and
set it to the new position via the available rolls.
456181/4-4 Wn
456181/4-5 Wn
Bsp: V = 1,52
|
1 689 989 226
2019-07-24