Construction for level
Electrical connection
Han 8D is identical to Han 8U.
1)
7.7
Display, keyboard and auxiliary power
Display and user interface
Keys
Display
Auxiliary power U
H
Terminal voltage on pressure
transmitter
Ripple
Noise
Auxiliary power
Separate supply voltage
Bus voltage
Not
For intrinsically safe operation
Current consumption
Max. basic current
Starting current ≤ basic current
Max. current in event of fault
Error shut-down electronics (FDE)
present
SITRANS P DS III/P410 (7MF4.33.. 7MF4.34.. 7MF4.35..)
A5E03434626-04, 05/2015
Screw terminals
Cable inlet using the following screwed joints:
Pg 13.5
M20 x 1.5
½-14 NPT or Han 7D/Han 8D connector
M12 connector
3 for on-site programming directly at the device
With or without integrated display (optional)
Cover with inspection window (optional)
HART
DC 10.5 V ... 45 V
In the case of intrinsically safe
operation 10.5 V ... 30 V DC
U
≤ 0.2 V (47 ... 125 Hz)
SS
U
≤ 1.2 mV (0.5 ... 10 kHz)
eff
1)
PROFIBUS PA or Foundation Fieldbus
Bus-powered
Not necessary
9 ... 32 V
9 ... 24 V
12.5 mA
Yes
15.5 mA
Yes