R911415883 | PRC 7x00-Lx/Wx-0130
No.
PRC7000 outputs
32..47
ForceSetPoint Bit0 – 15
48..63
SheetThickness Bit0 - 15
State Bit0 - 15
64..79
Not used
80..95
TipDressRequestStartVisu
96
TipDressRequestVisu
97
TipPrewarningVisu
98
TipEndOfLifeVisu
99
TimerReadyVisu
100
WeldingErrorVisu
101
TipDresserChangeRequestVisu
102
TipDresserChangeNecessaryVisu
103
GunChangeRequestVisu
104
GunChangeNecessaryVisu
105
Not used
106..111
DeviationVisu Bit0 - 7
112..119
RemaingPartsVisu Bit0 - 7
120..127
EchoTipNumberVisu Bit0 - 7
128..135
Description
About these outputs is
the current pressure setpoint for the proportional valve.
the value arises
from the current spotselection, the
Force correction and the current
adjustment factor
Output of the parameterized
Sheet thickness for the current
selected weld job
Output of the PRC 7000 timer states, see chapter 8 "Status
code".
Without function
Status output "StartTip dressing request" for the Tip selected
by TipNumberVisu
Status output "Tip dressing request" for the Tip selected by
TipNumberVisu
Status output "Tip change request" for the Tip selected by
TipNumberVisu
Status output "Tip change necessary" for the Tip selected by
TipNumberVisu
The system reports that the control part of the system is
ready and does not report any errors. This signal does not
include the status of the servo gun, which may be in a state
not ready for welding (e.g.: gun is undocked).
This output is set if a weld process was aborted or
ended with a welding fault.
For details see "Program start"
Status output "Tip dresser change request" for the Tip
selected by TipNumberVisu
Status output "Tip dresser change necessary" for the Tip
selected by TipNumberVisu
Status output "Gun change request" for the Tip selected by
TipNumberVisu
Status output "Gun change necessary" for the Tip selected
by TipNumberVisu
Without function
Deviation between the setpoint and the actual value in
percent when an error is present.
Description: Shows how many Spots can still be welded with
the current tip before it has to be changed.
Feedback actual selected Tip Number