GARANT XControl
de
3. NOTICE! If settings are configured on the machine controller, they will not be saved.
4. NOTICE! XConnect must be plugged into the same USB port as when determining the EXTCALL path.
ü XConnect is unplugged.
bg
ü Battery compartment cover of XControl is removed.
5. There is a button (1) above the battery.
6. Press button (1).
da
»
LED (2) must light up green.
7. Connect XConnect to USB port.
»
Green LED on XControl goes out.
en
8. Wireless connection is configured if:
»
Power LED (4) lights up green.
fi
»
Connect LED (5) lights up orange.
»
RSSI LED (3) is green.
9. Assemble battery compartment cover.
fr
10. Tighten screws of battery compartment cover with 1.2 Nm.
»
XConnect + XControl connected.
6.4.
CONNECTING XCONTROL + XCONTROL + XCONNECT
it
NOTICE! The last XControl to be connected is always in the first position of the two XControl devices. That is
important for usage in the "NC Program" or in the MDA.
hr
Connect the additional XControl in the same sequence as the first one. Connecting XControl + XConnect [} Page 49]
7.
Operation
lt
7.1.
SWITCHING ON
NOTICE! After 10 minutes of inactivity, the XControl switches to stand-by mode.
ü Battery is installed. Inserting the battery [} Page 49]
nl
1. Press contact point.
»
XControl switched on.
no
7.2.
POSITIONING THE XCONTROL
ü XControl is connected with XConnect.
1. Using a clamping device, position the XControl in the working area of the machine.
pl
2. Insert the reference tool (calibration mandrel) with the exact tool length into the spindle.
3. Position the reference tool (calibration mandrel) centrally approx. 5 mm above the contact point of the XControl.
4. Use the respective controller-dependent programs (Siemens/Heidenhain) to determine the position of the XControl in
pt
the machine coordinates system.
»
XControl is positioned.
ro
7.3.
SIEMENS AUTOMATED OPERATION
R-parameters R78-R96 are overwritten during the probing process. Collection of sub-programs comprises standard probe
cycles for the controller SINUMERIK 840D and 828D which must be saved on the controller in the user cycles area. Sub-pro-
sv
grams are configured for the G17-level. Probe cycles work exclusively with the XTouch. Probe processes with other devices
are not taking into account here and could leave to collisions on the machine.
Cycle
sk
G91 incremental
Probe cycle L_POS
sl
Probe cycle L_BREAK
Probe cycle L_LENGTH
es
Auxiliary cycle L_START(1)
Auxiliary cycle L_RESET(1)
cs
7.3.1.
Activation G91 (incremental)
When all probe cycles are started, the function G91 (incremental dimensions specifications) is activated. If the cycle is abor-
ted by the user, the controller must be switched to absolute dimensions specification G90 if required.
hu
Back to Siemens automated operation [} Page 50]
50
Link
Activation G91 (incremental) [} Page 50]
Probe cycle L_POS [} Page 51]
Probe cycle L_BREAK [} Page 51]
Probe cycle L_LENGTH [} Page 51]
Auxiliary cycle L_START(1) [} Page 52]
Auxiliary cycle L_RESET(1) [} Page 52]