9–15 kW
U
V W N
Fig. 2: Connection diagram
When measuring the insulation barrier of the heater, some leakage may occur, which is
caused by the humidity that has seeped into the insulation material during transport
or warehousing. The moisture will evaporate after the heater is heated a few times.
Do not connect the power supply for the electric heater through a fault current protection!
3. INSTALLATION:
3.1 INSTALLATION OF STOVE
- The heater is floorstanding.
- Observe the safety distances (Fig. 1) when installing the stove.
- Electrical connection of the stove may only be carried out by a qualified electrician in compliance with
valid regulations.
- The connection cable shall be a rubber sheathed cable of type H07RN-F or corresponding. Cable size
and fuse rating as indicated in Table 1.
- The protective film of the heaters casing and the cardboard support of the resistors need to be
removed before using the product.
- Read and follow carefully both the sauna heater's and the control unit's manuals.
- The highest temperature in the sauna cabin is always measured in the area above sauna heater. The
temperature sensor and safety device must be installed to the above-mentioned area as described in
manuals.
- The temperature sensor must be istalled in such way, that it does not get influenced by the cold air
coming from outside (e.g. door, window, ventilation).
4. LOADING OF STONES
- Use safety gloves.
- When loading the stones, make sure they do not bend the
resistors or obstruct sufficient circulation of air.
- Do not load the stones too tightly. Over-filling of the stone
compartment will cause overheating of the resistors
(= shorter service life) and slower heating up of the sauna.
- The stones shall cover the heating resistors completely.
- Sauna stones must be replaced every 6 months.
- The peripheral area of the stone space must, however,
be piled as tightly as possible to cover the resistors.
- Ceramic stones cannot be used in this heater!
AN UNDER-FILLED STONE COMPARTMENT WILL
CAUSE A FIRE HAZARD!
18–30 kW
U V W
N
U
V
W
N