10.3 Selecting a wind mode
Use the remote control (11) to change the wind mode. Press the Mode button (e) on the remote
control to switch between wind modes.
Normal Mode: The wind flow will be constant at the speed selected.

Natural Mode: The wind pattern varies at the speed selected to mimic outdoor breezes.

– HIGH alternates between High, Medium and Low speeds.
– MEDIUM alternates between Medium and Low speeds.
– LOW alternates between Low and Off.
Sleep Mode: The fan will operate at the selected speed in Natural Mode, decreasing the

speed every 30 minutes until reaching LOW.
– The Natural and Sleep indicator lights will be off in Normal Mode, and will illuminate in
the corresponding mode when selected.
10.4 Setting the auto-off timer
After you set an auto-off timer, the fan turns off when the timer elapses. You can set a timer
from 0.5 to 8 hours.
1. Turn the fan on.
2. Press the timer button (d, C) to activate the timer mode.
3. Repeatedly press the timer button until you reach the desired time.
The set time will be shown on the display (E).
Æ
The fan will turn off at the end of the timer.
Æ

11 Cleaning and care

Important:
– Do not use harsh cleaning agents, rubbing alcohol or other chemical solutions. They
damage the housing and can cause the product to malfunction.
– Do not rinse the product under the tap or expose to moisture.
– Do not immerse the product in water.
1. Disconnect the product from the power supply.
2. Clean the body and motor housing with a soft cloth slightly moistened with water or soapy
water.
3. Clean the grilles with a damp cloth.
4. For a thorough cleaning, disassemble the fan head to clean the parts separately. Refer to
"8 Assembling the fan" on page 5.
5. Allow all parts to dry completely before reassembling and using the fan.
12 Disposal
12.1 Product
This symbol must appear on any electrical and electronic equipment placed on the
EU market. This symbol indicates that this device should not be disposed of as
unsorted municipal waste at the end of its service life.
Owners of WEEE (Waste from Electrical and Electronic Equipment) shall dispose
of it separately from unsorted municipal waste. Spent batteries and accumulators,
which are not enclosed by the WEEE, as well as lamps that can be removed from
the WEEE in a non-destructive manner, must be removed by end users from the
WEEE in a non-destructive manner before it is handed over to a collection point.
Distributors of electrical and electronic equipment are legally obliged to provide free take-back
of waste. Conrad provides the following return options free of charge (more details on our
website):
in our Conrad offices

at the Conrad collection points

at the collection points of public waste management authorities or the collection points set

up by manufacturers or distributors within the meaning of the ElektroG
End users are responsible for deleting personal data from the WEEE to be disposed of.
It should be noted that different obligations about the return or recycling of WEEE may apply in
countries outside of Germany.
12.2 (Rechargeable) batteries
Remove batteries/rechargeable batteries, if any, and dispose of them separately from the
product. According to the Battery Directive, end users are legally obliged to return all spent
batteries/rechargeable batteries; they must not be disposed of in the normal household waste.
Batteries/rechargeable batteries containing hazardous substances are labelled
with this symbol to indicate that disposal in household waste is forbidden. The
abbreviations for heavy metals in batteries are: Cd = Cadmium, Hg = Mercury,
Pb = Lead (name on (rechargeable) batteries, e.g. below the trash icon on the left).
Used (rechargeable) batteries can be returned to collection points in your municipality, our
stores or wherever (rechargeable) batteries are sold. You thus fulfil your statutory obligations
and contribute to environmental protection.
Batteries/rechargeable batteries that are disposed of should be protected against short circuit
and their exposed terminals should be covered completely with insulating tape before disposal.
Even empty batteries/rechargeable batteries can contain residual energy that may cause them
to swell, burst, catch fire or explode in the event of a short circuit.
on page

13 Technical data

13.1 Power supply
Input voltage/current ..........................220 – 240 V/AC, 50 Hz, 0.23 A
Rated power ......................................50 W
13.2 Remote control
Battery .............................................. 3.0 V, 2x 1.5 V AAA batteries
13.3 Environment
Operating conditions ......................... +20 to +80 °C, 20 – 85 % RH (non-condensing)
Storage conditions ............................ 0 to +80 °C, 20 – 85 % RH (non-condensing)
13.4 Other
Number of blades ..............................5
Speed levels ......................................3
Timer .................................................0.5 hr – 7.5 hr
Oscillation angle ................................90° left-right
Blade rotation speed ..........................max. 1250 RPM
Mains cable (L) ..................................1.6 m
Dimensions (W x H x D) ....................355 x 465 x 465 mm
Weight ...............................................4.3 kg
13.5 Data according to EU regulation 206/2012
Description
Maximum fan flow rate
Fan power input
Service value
Standby power consumption
Off power consumption
Fan sound power level
Maximum air velocity
Seasonal electricity consumption
Measurement standard for service value
Contact details for obtaining more
information
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). All rights
including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data
processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication
represents the technical status at the time of printing.
Copyright 2023 by Conrad Electronic SE.
Symbol
Value
Unit
F
67.63
m
/min
3
P
50.90
W
SV
1.33
(m
/min)/W
3
P
0.13
W
SB
P
---
W
OFF
L
65.31
dB(A)
WA
C
2.91
meters/sec
Q
16.43
kWh/a
EN IEC 60879:2019
Conrad Electronic SE, Klaus-Conrad-Str. 1,
D-92240 Hirschau