On Grid always on: When click "on Grid always on" the smart load will switch on when the grid is present.
Solar Power: Power limiter to the maximum power allowed to the Aux load.
Aux Load OFF Batt Battery SOC at which the Smart load will switch off.
Aux Load ON Batt: Battery SOC at which the Smart load will switch on. Also, the PV input power should
exceed the setting value (Power) simultaneously and then the Smart load will switch on.
For Micro Inverter Input mode:
Micro Inverter Input: To use the Generator input port as a micro-inverter on grid inverter input (AC cou-
pled), this feature will also work with "Grid-Tied" inverters. Tick this box if intending to connect a supplemen-
tary inverter or micro inverter (Max. 4kW).
AC Couple OFF Batt: When the battery SOC exceeds setting value, Microinveter or the grid-tied inverter will
shut down.
AC Couple ON Batt: If choosing"Micro Inv input", as the battery SOC reaches a gradually setting value (OFF),
During the process, the microinverter output power will decrease linearly. When the battery SOC equals
to the setting value (OFF), the system frequency will become the setting value (AC couple Fre high), and the
Microinverter will stop working. Stop exporting power produced by the microinverter to the grid.
PLEASE NOTE
Micro Inv Input OFF and On is valid for certain FW versions only.