Round head drive
For drives greater than 25 Nm, use an adapted support referenced by Somfy.
1] Install the support (i) on the drive head, then the removable end caps (k).
2] Slide the tube-drive-removable end cap assembly into the head rail.
2.1.5.Wiring
WARNING
Comply with Standard NF C 15-100 for electrical installations.
PRECAUTION
• Cables routed through a metal wall must be protected and insulated by sleeving or sheathing.
• Secure the cables to prevent any contact with moving parts.
• If the drive is used outdoors and if the power supply cable is of the H05-VVF type, run the cable in a UV-resistant
duct, e.g. trunking.
• The drive cable is removable. If it becomes damaged, replace it with an identical cable.
CAUTION
• Leave the drive power supply cable accessible: it must be easily replaceable.
• Always make a loop in the power supply cable to prevent water from entering the drive.
1] Switch the power supply OFF.
2] Connect the drive and the wired control point according to the information
provided in the table below.
3] Switch the power ON
230 V
50 Hz

3.COMMISSIONING

NOTICE
This guide describes drive set-up using a Somfy io-homecontrol® local control point. A Somfy io-homecontrol® local
control point is a one-way radio transmitter.
Identification of the set-up steps already performed
CAUTION
Power must only be supplied to one drive at a time.
Three different reactions allow the drive status to be identified. Switch off the power for two seconds on a single motorised
product to identify the drive's status:
▪ Reaction 1:
◦ The motorised product moves up and down briefly upon power-up.
◦ The end limits have been set and no control point is programmed.
See section Pre-programming the control point [}  6] then section Programming the first local io-homecontrol
point [} 10].
©
Copyright
2022 SOMFY ACTIVITES SA. All rights reserved.
Cables
Neutral (N)
Phase (L)
Blue
Brown
1]
k
2]
Earth ( )
Green-Yellow