7. Test if your smoke alarm were connected successfully by pressing the test button of a random
device until it beeps. The red LED of all connected devices will flash twice per second for five
minutes. Stop these alarms by pressing the test button of each alarm.
Reset connection
1. Disconnect the smoke alarm you want to reset by removing it from the mounting plate, or by
pushing the activation switch to the "A" position with a screwdriver.
2. Press and hold the test button and activate the smoke alarm again by pushing the activation
switch to the "B = ON" position.
3. Hold the test button while the LED lights up red and release it when the LED turns of.
4. When the LED lights up again, press the test button.
5. The LED will start flashing to indicate that it the network is being cleared.
6. When the LED turns off, the connection is successfully cleared.
7. Repeat step 1 to 6 for disconnecting more smoke alarms.
Mounting
(view page 1_C-D-E)
• Place the mounting plate on the desired installation location and mark where the holes should be
drilled.
• Drill two holes with a diameter of 5 millimeters.
• Push the plastic plugs into the holes.
• Insert the screws into the mounting plate and tighten them firmly into the plugs.
• Place the smoke alarm on the mounting bracket and secure it by turning it clockwise.
• Test the correct operation of your smoke alarm by pressing the test button. If no sound is
generated, the smoke alarm is not functioning properly and should not be used!
Alarm silence facility
When the smoke alarm has detected smoke and turns into the alarm mode, you can mute the alarm
for a minimum of 5 minutes and a maximum 15 minutes by pressing the test button. After that, the
smoke alarm automatically resets and returns into the normal operation mode. If there are still
particles of combustion in the air, the smoke alarm will turn into the alarm mode again. WARNING:
Before using the alarm silence facility, always identify the cause of the alarm and make sure that the
circumstances are safe.
Low battery mode
When the battery is running low, the smoke alarm will indicate this with a repetitive beep and flash
for approximately 30 days. WARNING: This smoke alarm is equipped with a non-replaceable battery.
When this warning occurs, replace the device as soon as possible! The acoustic low battery warning
signal can be muted for ten hours by pressing the test button. The smoke alarm is still functioning
and able to detect smoke when it's in this mode.
Fault warning mode
When the smoke alarm is not functioning properly, it will turn into the fault warning mode. Try
cleaning the smoke alarm (see paragraph maintenance) or replace the smoke alarm!