Service Test Programme
23a (VideoColDencOn)
Diagnostic Nucleus VideoColDencOn enables colour bar in the DENC
in the STi5505.
Correct operation cannot be detected by the Diagnostic Software but
must be checked externally.
23b (VideoColDencOff)
Diagnostic Nucleus VideoColDencOff disables colour bar in the DENC
in the STi5505.
Correct operation cannot be detected by the Diagnostic Software but
must be checked externally.
25 (VideoScartLo)
VideoScartLo steers pin16 on the Euro AV connector with the value
Low (0 to 2V)
Correct operation cannot be detected by the Diagnostic Software but
must be checked externally.
25 (VideoScartMi)
VideoScartMi steers pin16 on the Euro AV connector with the value
Medium (4.5 to 7V)
Correct operation cannot be detected by the Diagnostic Software but
must be checked externally.
25 (VideoScartHi)
VideoScartHi steers pin16 on the Euro AV connector with the value
High (9.5 to 12V).
Correct operation cannot be detected by the Diagnostic Software but
must be checked externally.
26 (DispVer)
Get version number of the slave processor on the Display PWB
27 (DispKeyb)
Checks that all keys will be pressed once (arbitrary sequence). Feed
back will be given via the local display for each key that has been
pressed. The test will be terminated by pushing the NEXT key for at
least 1 second.
28 (DispRc)
Displays Header, System and Command code for each received RC
code on the local display. If the first key that is pressed is the PLAY-key,
the remote-control test will not be executed, but the region code can be
changed. The remote control test can be left by pressing the NEXT key
on the local keyboard.
29 (DispLed)
Lights all local LEDs until the NEXT key on the local keyboard is
pressed.
30 (DispDisplay)
Displays test patterns on the local display until the NEXT key on the
local keyboard is pressed. Test patterns can be walked through by
pressing PLAY (next pattern) and PAUSE (previous pattern).
Note: For the specification of the test patterns see page 3-10.
31 (LogReadErr)
Read error log from NVRAM and output the data as error numbers only.
32 (LogReadBits)
Read error bits from NVRAM and output the numbers of the error bits
which are set.
33 (LogReset)
Reset all error log and bits in the NVRAM.
34 (MiscReadConfig)
Read configuration area from NVRAM and output as raw data.
35 (MiscNvramReset)
Reset the whole NVRAM to zero.
After resetting the NVRAM the Player must be reactivated (page
1-7)!
36 (MiscNvramMod)
Read/Modify any location in NVRAM.
37 (BeVer)
Get version number of the Drive Mechanism.
38a (BeFocusOn)
Diagnostic Nucleus BeFocusOn puts the laser of the BE into focus
(focus loop).
38b (BeFocusOff)
Diagnostic Nucleus BeFocusOff switches the focus loop off.
3 - 16
39a (BeDiscmotorOn)
BeDiscmotorOn switches the disc motor (=spindle motor) on
39b (BeDiscmotorOff)
BeDiscmotorOff switches the disc motor (=spindle motor) off
40a (BeRadialOn)
Diagnostic Nuclei BeRadialOn closes the radial loop
40b (BeRadialOff)
Diagnostic Nuclei BeRadialoff opens the radial loop
41a (BeSledgeIn)
Diagnostic Nuclei BeSledgeIn moves the sledge fully inwards.
41b (BeSledgeOut)
Diagnostic Nuclei BeSledgeOut moves the sledge fully outwards.
42a (BeGroovesIn)
Diagnostic Nuclei BeGroovesIn lets the laser spot jump to the inside
limit of the disc.
42c (BeGroovesMid)
Diagnostic Nuclei BeGroovesMid lets the laser spot jump to the middle
of the disc.
42c (BeGroovesOut)
Diagnostic Nuclei BeGroovesOut lets the laser spot jump to the outside
limit of the disc.
43a (BeTrayIn)
Diagnostic Nucleus BeTrayIn closes the disc tray.
43b (BeTrayOut)
Diagnostic Nucleus BeTrayOut opens the disc tray.
44 (BeReset)
Reset the Drive Mechanism.
45 (MiscPalNtscHi, MiscPalNtscLo)
Check if the PAL/NTSC line on the STi5505 is high or low. The result
of this nucleus depends on the input signal that is put on this line
externally by an operator.
46 (MiscApplVer)
Read the version of the application software from the NVRAM.
47 (MiscBePlayTime)
Read the playtime of the Drive Mechanism from a fixed location in the
NVRAM.

5. Error messages

Drive Mechanism
Bit
Error
Meaning
0
illegal-command
Command not allowed in this state or unknown
1
illegal_parameter
parameter not valid for command
2
sledge_error
sledge could not be moved to home position
3
focus_error
focus failure
4
motor_error
motor not on speed within time-out
5
radial_error
servo didn't get on track after several retries
6
pll_lock_error
PLL could not lock in Accessing or Tracking
state
7
subcode_header_
subcode or sector information could not be
time_out
read
8
subcode_not_
requested subcode item could not be found
found
9
tray_error
tray could not be closed or opened completely
10
toc_read_error
TOC read could not be read in time
11
jump_error
Set when a seek couldn't be performed
12
non_existing_
datapath tries to access a non existing lead
session
in area
13
non_existing _bca
datapath tries to access a non existing bca area
14
over-run error
too many bytes received over S2B
15
communication
too less bytes are received over S2B time out
16
parity error
byte received with a parity error
17
illegal bus phase
CMD_IDC is not valid: out of sync
18
illegal number
more bytes are transmitted than possible
of bytes