Herunterladen Inhalt Inhalt Diese Seite drucken

Temperature Display; Battery Replacement; Maximum And Minimum Values - TFA 30.5032 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für 30.5032:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
TFA_No. 30.5032_Anleit_03_23
Mould RADAR thermo-hygrometer
• Press any button to stop the alarm sound.
• The warning light continues flashing until the measured humidity is below 65%.
• Slide the left switch (speaker symbol) back using a pin and the alarm sound is deactivated.
8.4 Comfort level
• The device shows two different indicators for the comfort level of the indoor climate:
• Smiling face: ideal values (40-60%)
• Sad face: too wet or too dry (< 40% or > 60%)
8.5 Display dew point
• With the switch inside the battery compartment can you change between the indication
"Taupunkt"" (position left) or "dew point" (position right). Use a pin to slide the switch.
• Press the Taupunkt button to show the current dew point.
• On the display "Taupunkt" or "dew point" will be flashing and the current temperature
appears briefly.
• The display automatically returns to the current temperature and humidity.
This interdependency of temperature and relative humidity is expressed by means of the
dew point:
• If the air is cooled continuously at constant absolute humidity, then the relative humid-
ity will steadily increase up to a maximum of 100%. If the air is cooled
further, then the excess water vapor is separated out in the form of water droplets.
• If the measuring unit indicates an air temperature of 20 °C and a relative humidity of 65%,
then the dew point temperature will be 13.2 °C. What does that mean? That the air, for
instance in your bedroom, will condense and from water droplets at all points on walls
and ceilings that are cooler than 13.2 °C, and that this may later lead to patches of mould
or damp.
• If the air is at a relative humidity of say 40%, then the dew point temperature is only 6 °C.
The walls and ceilings would therefore have to be significantly colder for the air to reach
its dew point and for water droplets to form.

8.6 Temperature display

• Press and hold the Taupunkt button (5 seconds) to change between °C (Celsius) or °F
(Fahrenheit) as temperature unit.

8.7 Maximum and minimum values

• Press the min/max button.
• max appears on the display.
• The highest indoor temperature and humidity are displayed since the last reset.
• Press the min/max button again.
• min appears on the display.
14
05.03.2023
10:37 Uhr
Seite 8
Mould RADAR thermo-hygrometer
• The lowest indoor temperature and humidity are displayed since the last reset.
• The instrument will automatically quit the MAX/MIN mode if no button is pressed or press
the min/max button again to return to the current display.
• Press and hold the Taupunkt button (3 seconds) when the highest or lowest values are
displayed to reset the display values to the current state.
9. Standing or hanging
• With the suspension device you can hang the instrument on the wall using a nail or a
screw.
• For table standing use the attached support.
• Since the humidity level within rooms can vary greatly according to the location, mount
the unit so that it will monitor the conditions in a location likely to be subject to the most
problems.
10. Care and maintenance
• Clean your instrument with a soft damp cloth. Do not use solvents or scouring agents.
• Remove the batteries if you do not use the product for a long period of time.
• Keep the instrument in a dry place.

10.1 Battery replacement

• Change the batteries when the battery symbol appears on the display.
• Open the battery compartment and insert two new batteries 1,5 V AAA. Make sure the
polarities are correct.
• Close the battery compartment again.
11. Troubleshooting
Problem
Solution
No indication /
Ensure that the battery polarity is correct
Incorrect indication
Change the batteries
If your device fails to work despite these measures contact the supplier from whom you pur-
chased it.
12. Waste disposal
This product and its packaging have been manufactured using high-grade materials and com-
ponents which can be recycled and reused. This reduces waste and protects the environment.
Dispose of the packaging in an environmentally friendly manner using the collection systems
that have been set up.
15

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis