Herunterladen Inhalt Inhalt Diese Seite drucken

Dip Switches - Abus CASA10010 Installationsanleitung

Ip alarmmodul
Vorschau ausblenden Andere Handbücher für CASA10010:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

3.5

Dip switches

The dip switches have the following meanings:
1. OFF: The IP alarm module trains wireless transmitters via
infrared LED only.
ON: The IP alarm module trains wireless transmitters via
wireless protocol only.
2. OFF: The IP alarm module does not monitor jamming.
ON: The IP alarm module monitors jamming.
3. OFF: The IP alarm module does not monitor the detectors
for supervision.
ON: The IP alarm module monitors the detectors for
supervision failures.
4. OFF: Short supervision time (20 minutes).
ON: Long supervision time (3 hours).
5. Must be set to OFF.
6. Must be set to ON.
7. Must be set to ON.
8. Must be set to OFF.