PRODUCT SPECIFICATION

GENERAL
PARAMETER
DESCRIPTION
- Temperature (T)
- Relative Humidity (RH)
Detection
- Carbon Dioxide (CO )
Parameters
- Particular Matter (PM1.O, PM2.5 and
PM10)
- Total Volatile Organic Compound (TVOC)
Display
Mono segment display
Direct : 24 V AC/DC ± 20 %
Power Supply
Sylk
TM
TR50-5D: 24 VAC 3.8 VA, 24 VDC 1.2 W
TR50-5N: 24 VAC 3.8 VA, 24 VDC 1.2 W
TR50-3D: 24 VAC 3.2 VA, 24 VDC 1.O W,
Power Consumption
Sylk
TM
TR50-3N: 24 VAC 3.2 VA, 24 VDC 1.O W,
Sylk
TM
Operating
0 - 50 °C (32 - 122 °F)
Temperature
Operating Humidity
0-95 % RH, non-condensing
Storage
-40 - 65.5 °C (-40 - 150 °F)
Temperature
Communication
BACnet MSTP, Modbus over RS485, or Sylk
Net weight
189 grams (0.42 lbs.)
Enclosure
Polycarbonate
IP protection level
IP20
Junction Box
US single vertical, BS single, ME single, EUR
compatibility
single
The device can be mounted on drywall/
Surface mount
stone/etc. in retrofit cases.
Use to switch screens on the device from one
Touch Button
parameter to another.
USER INTERFACE
PARAMETER SPECIFICATION
The LED light behavior can be configured into two modes. It shows
LED behavior, air quality, sensor reading level or sensor health.
LED
Behavior
Green
Color Mode
Yellow
Red
White On
White Breath Medium
Neutral Mode
White Blink
TM
: Honeywell Sylk
Bus Technology
1.0 W
1.0 W
Sensor
Air Quality
Reading
Level
Level
Good
Good
Medium
Medium
Poor (For
Poor
CO
, PM2.5
2
and TVOC)
Good
Good
Medium
Poor (For
Poor
CO
, PM2.5
2
and TVOC)
SENSING
PARAMETER DETAIL
Measuring range
Sensor output resolution
Temperature
Accuracy (According to
Alcohol Volatilization)
Measuring range
Sensor output resolution
Humidity
Accuracy
Measuring range
Sensor output resolution
CO
2
Accuracy
Measuring Range
TM
Sensor output resolution
PM1.0
PM2.5
Accuracy
PM10
(According to
GRIMM
Technology)
Measuring range
Sensor output resolution
TVOC
Accuracy (According to
Alcohol Volatilization)
DISPLAY OPTIONS*
Sensor
Health
PARAMETER
Air Quality
Sensor Reading
Sensor
Failure
Error Code
*Only available in TR50-5D and TR50-3D models.
SCALABILITY
The IAQ Sensors are open protocol and can connect
to any controller using BACnet and Modbus.
Sensor
The Sylk
TM
bus connectivity is compatible with
Failure
Honeywell Optimizer Suite controllers and limited
compatibility with the Honeywell Spyder model.
Indoor Air Quality Sensor TR50 -Product Datasheet |
SPECIFICATION
0 - 50 ⁰C (32 - 122 ⁰F)
0.1 ⁰C (0.1 ⁰F)
± 1 ⁰C (± 1.8 ⁰F)
0 - 100 % RH
0.1 % RH
±5 % RH @ 10 -
90 % RH in Room
Temperature
0-9999 ppm
1 ppm
± 75 ppm @ 400-
1000 ppm.
± 40 ppm ± 5 % reading
@ 1001-2000 ppm
0 - 5000 µg/m
1 µg/m
± 10 µg @ 0-100 µg/m³
PM1.0
± 10 % reading @ 101-
500 µg/m³
± 10 µg @ 0-100 µg/m³
PM2.5
± 10 % reading @ 101-
500 µg/m³
± 25 µg @ 0-100 µg/m³
PM10
± 25 % reading @ 101-
500 µg/m³
0-9999 ppb
0.1 ppb
± 25 % reading
SPECIFICATION
Indoor Air Quality value
Temerature, Humidity, CO
value
2
PM2.5, TVOC value (Only available in TR50-5D)
In case of sensor failure, the display will show the
sensor name and Err.
For example, in the case of PM2.5 sensor failure,
the display will show the error code as Err
If more than one sensor fails, the display will
switch among those failure sensors.
www.honeywell.com
3