〈4〉 Removal of the slider holder
Remove the four M2.6 mounting screws for the slider
holder and then remove the slider holder itself.
• Be sure to adhere the screening label (accessory) to
cover the screw holes after removing the slider holder. If
these holes are not plugged, chips, cutting oil or dust may
enter and the accuracy of the scale may be deteriorated.
Use a ball-point pen to enter the mounting date and name
of the person responsible on the label.
Remove the four M2.6 screws.
Slider holder
Adhere the screening label
(accessory).
Fig. 3-12 Removal of slider holder
Note
Keep slider holder and four M2.6 screws after the
52
installation.
〈5〉 Checking of the operating range
After mounting the scale and slider, be sure to move the
machine over the overall length of the scale to check that
the machine moves within the measuring length.
Remember that the scale may be damaged if the machine
moves beyond the movable range of the slider (measuring
length + leeway).
〈6〉 Mounting of the headcable
Fix the head cable with cable clamps so that they will not
interfere with moving parts of the machine.
Secure the cable clamp using a M4×10
cable clamp screw (accessory).
Fig. 3-13