4.7 ADJUSTING THE MAIN PAGE
4.8 DATA STORAGE SETTINGS
Press SHIFT + 0 to enter the system settings menu. Now press the right arrow key to enter the home page
settings menu. Press ENTER and then use the direction key to set the classic style or the curve style.
CLASSIC STYLE: The classic style is the default style of the system and displays voltage, current and power
in large font.
CURVE STYLE: The curve style displays the output voltage, current and power in a color-coded curve. Here,
D defines the scale of the ordinate. ENTER can be used to stop or continue the automatic curve progression.
The encoder can be used to scale the ordinates of the curves.
Press SHIFT + 0 to enter the system settings menu. Now press the right arrow key twice to call up the settings
menu for data storage. Use the direction keys to select the desired data group.
I-SET: Setting the memory output current
V-SET: Setting the memory output voltage
SHIFT + I-SET: Setting the memory overcurrent protection limit
SHIFT + V-SET: Setting the memory overvoltage protection limit
29