Herunterladen Inhalt Inhalt Diese Seite drucken

Safety Instructions; Technical Data; Conformity With Standards - Eaton Serie: eLL. 92 LED 400 Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

1

Safety instructions:

For skilled electricians and
instructed personnel in accordance
with national legislation, including the
relevant standards and, where applicable,
in acc. with IEC/EN 60079-14 on electrical
apparatus for explosive atmospheres.
– The light fitting must not be operated in
zone 0 and 20 hazardous areas!
– The light fitting must not be use while
excessive deposit of dust
(accd. IEC/EN 60079-31) exist.
– The technical data indicated on the light
fitting are to be observed!
– Changes of the design and modifications to
the light fitting are not permitted!
– The light fitting shall be operated as
intended and only in undamaged and
perfect condition!
– Only genuine Eaton's Crouse-Hinds
Business (Eaton) / CEAG spare parts may
be used for replacement!
– Do not keep these operating instructions
inside the light fitting during operation!
The national safety rules and regulations for
pre vention of accidents and the following
safety in structions which are marked with
an (
) in these operating instruction, will
have to be observed!
3.

Conformity with standards

The light fittings meet the requirements of the
following standards:
CAN/CSA-E60598-1:12
CAN/CSA-C22.2
No. 60079-0:11
CAN/CSA-C22.2
No. 60079-1:11
CAN/CSA-C22.2
No. 60079-7:12
CAN/CSA-C22.2
No. 60079-18:12
CAN/CSA-C22.2
No. 60079-31:12
CAN/CSA-C22.2
No. 60529:05 (10)
UL 1598:08
UL 844:12
UL 60079-0:13
UL 60079-1:09
UL 60079-7:13
UL 60079-18:12
UL 508:07
UL 50:12
Explosion protected light fittings
Series: eLL. 92 LED 400 and eLL. 92 LED 800
2.

Technical data

Certification:
Explosion category:
Permissible LED Module:
Permissible lamps
Philips
GE
Osram/Sylvania
Philips
GE
Osram/Sylvania
Insulation class accd. to EN/IEC 61140
Degree of protection accd. to EN/IEC 60529
Permissable ambient temperatures
eLL. 92 ...
Storage temperature in original packing
Supply terminal clamping capacity
2 x per terminal
min.
max.
Conductor cross-section with through-wiring
Cable entries:
standard version
1)
Intensive sun radiation in areas of high ambient temperatures may cause inadmissible temperature
rise inside of the luminaire. This may result a decrease in lifetime of the electronic ballast (EVG).
Therefore those luminaires should be switched off during daytime by a photocell control.
4.
Installation
The respective national regulations as well
as the general rules of engineering which
apply to the installation and operation of
explosion protected apparatus will have to
be observed (IEC/EN 60079-14)!
Transport and storage of the luminaire is
permitted in original packing and specified
position only!
4.1
Mounting
see fig. 2.1
The integrity of the fitting may be
compromised if the fixing centres are not
correctly aligned, see fig. 2.10-2.11. When
fixing the mounting accessories onto the
light fitting, observe the max. depth of
thread of 14 mm!
Do not use too long screws!
Installing the light output upwards
additional protection has to be assembled to
avoid permanent water accumulations at
the protective bowl gasket area.
EATON's Crouse-Hinds Business
C
US LISTED
CSA 14.70011905
Class I Div. 2 Group A, B, C und D
Class II Div. 1 Group E, F und G
Class 1 Zone 1 AEx de mb IIC T4 Gc
Zone 21 AEx tb IIIC T80°C Db
Ex de mb IIC T4 Gc
Ex tb IIIC T80°C Db
CCH LED Modul 400
CCH LEB Modul 800
CSA 14.70011695
F17T8/TL 841
F17T8/SPX 41
F017/ 841
F32 T8/TL841
F32 T8/SPX41
F032/ 841
I
IP66/67
1)
-25 °C to +45 °C
-25 °C to +60 °C
single-wire
2
1.5 mm
AWG 15
2
6.0 mm
AWG 10
2.5 mm
2
(AWG 14) for max. 16 A
Hubs M25 - 3/4'' NPT
incl. blind plug M25 x 1.5
Mind:
For handrail mounting (e.g. mounted at 45°) we
recommend replacing the existing cover of the
locking bolt with the version part no
22216904000.
Accessories for mounting:
See Eaton/CEAG catalogue.
E
-13 °F to +113 °F
-13 °F to +140 °C
multi-wire
2
1.5 mm
AWG 15
2
6.0 mm
AWG 10
9

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Serie: ell. 92 led 800

Inhaltsverzeichnis