Legende

Warning
This symbol warns of a serious hazard.
Failure to observe this warning may result
in death or the destruction of property.
Caution
This symbol warns of a possible failure.
Failure to observe this caution may result
in the total failure of the device or the
system or plant to which it is connected.

1.1 Safety instructions

For skilled electricians and
qualified personnel in accordance
with national legislation, including
the relevant standards and, where applica-
ble, in acc. with IEC/EN 60079-14 on
electrical apparatus for explosive
atmospheres.
– The light fitting must not be operated in
zone 0 or 20 hazardous areas!
– The technical data indicated on the light
fitting are to be observed!
– The requirements of the
IEC/EN 60079-31 regarding excessive
dust deposits and temperature to be
considered from the user.
– Changes of the design and modificati-
ons to the light fitting are not permit-
ted!
– The light fitting shall be operated as
intended and only in undamaged and
perfect condition!
– Do not keep these operating instruc-
tions inside the light fitting during
operation!
The national safety rules and regulations
for pre vention of accidents and the
following safety in structions which are
marked with an (
instruction, will have to be observed!
Downloaded from
www.Manualslib.com
Explosion protected LED-Emergency Exit Luminaire
Series: Ex-Lite N; Ex-Lite NLT
2
EC-Type Examination Certificate:
Marking acc. to 2014/34/EU and standard of series
EN 60079
N
NLT
N/NLT
IECEx Certificate of Conformity:
Category of application standard of series IEC 60079
IEC 60079
N
N
Rated voltage
N
NLT
* max. permissable tolerances accd. IEC/EN 60079-0
Frequency:
Rated current
N
NLT
Battery module:
Charging time (cap. > 90 %):
Duration of emergency lighting:
(**)
Insulation class to IEC/EN 61140:
Degree of protection accd. IEC/EN 60529:
Operation temperature
N
NLT
Specified data N
Specified data NLT
Storage temperature in original packing:
Weight:
Supply terminal clamping capacity:
Ex-e cable entry standard version:
Standard version
suitable cables and test torques of the
pressure screw
Seal 1+2+3
Seal 1+2
Seal 1
(1)
The tests of clamping ranges and torque values were performed with metal mandrel. The clamping range can
vary by using cables with different manufacturing tolerances and material properties. Please use a suitable
) in these operating
combination of seals in the intermediate area, so that the cap nut can be tightened in future maintenance
work on the cable entry.
Metall version
Test torque for screw in thread cable entry:
manuals search engine

Technical data

ta
+ 40 °C:
max
ta
+ 50 °C:
max
ta
+ 40 °C:
max
ta
+ 40 °C:
max
ta
+ 50 °C:
max
AC:
DC:
AC:
110 V AC/DC:
220 V AC/DC:
heating:
Note: New batteries will reach their total useful capacity only after 3 charging/discharging cycles.
min.
1 2
3
max.
min.
1 2
3
max.
min.
1 2
3
max.
for screw in thread cable entry:
for cover screw
for screw fixing:
BVS 09 ATEX E 048
II 2 G Ex e ib mb IIC T5 Gb
II 2 G Ex e ib mb IIC T4 Gb
II 2 G Ex d e ib mb IIC T4 Gb
II 2 D Ex tb IIIC T80°C Db
IECEx BVS 13.0016
Ex e ib mb IIC T5 Gb
Ex e ib mb IIC T4 Gb
Ex tb IIIC T80°C Db
110 V - 277 V *
110 V - 250 V *
110 V - 240 V *
50 - 60 Hz
approx. 0.06 A
approx. 0.035 A
approx. 0.5 A / 50 W
Accu 2 x 6 V / 0,8 Ah
24 h
(**)
3 h
I
IP 66
-20 °C ... +40 °C/+50 °C
-40 °C ... +40 °C
+5 °C ... +35 °C
-40 °C ... +35 °C
-20 °C ... +50 °C
approx. 6.7 kg
2 x per terminal: 2.5 mm²
1x M25x1.5 blanking plug
M25 x 1.5
Ø cable (mm)
Nm
8.0
1.5
(1)
10.0
2.0
10.0
2.3
(1)
13.0
2.6
13.5
1.3
(1)
17 .5
2.3
2x M20x1.5 thread
3.0 Nm
2.4 Nm
1.4 Nm