Safety Instructions; Technical Data; Conformity With Standards - Eaton Crouse-Hinds LLK 98 018/18 Betriebsanleitung

Industrieleuchte
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

1.

Safety instructions:

For skilled electricians and trained
personnel in accordance with
national legislation, including the relevant
standards.
– The technical data indicated on the light
fitting are to be observed!
– Changes of the design and modifica-
tions to the light fitting are not
permitted!
– The light fitting shall be operated as
intended and only in an undamaged and
perfect condition!
– Only genuine Cooper Crouse-Hinds
(CCH/CEAG) spare parts may be used
for replacement!
– Repairs may only be carried out by
(CCH/CEAG) or a qualified "electrician"!
– These operating instructions shall not
be kept inside the light fitting during
operation!
The national safety rules and regulations
for prevention of accidents and the
following safety instructions which are
marked with an (
) in these operating
instructions shall be observed!
8
Industrial Luminaire Series: LLK 98
2.

Technical data

Light fittings with G13 bi-pin cap:
LLK 98 018/18
LLK 98 036
LLK 98 036/36
LLK 98 058
LLK 98 058/58
Lamps to be fitted:
Fluorescent lamps with G13 bi-pin cap to:
18 W
36 W
58 W
Insulation class to IEC/EN 61140:
Protection acc. to IEC/EN 60529:
Perm. ambient temperature:
Storage temperature in original packing:
Supply terminal clamping capacity
2 x per terminal
min.
max.
Supply terminal clamping capacity per clamp-
terminal (2.5 mm²):
Conductor cross-section with through-wiring:
Cable entry
Standard version
Suitable cables and test torques of the pressure
screw
seal 1+2
min.
1
2
(1)(2)
max.
seal 2
min.
1
2
(2)
max.
Test torque for screw in thread cable entry
Metal (optional)
Weight of light fittings:
LLK 98018/18:
LLK 98036:
LLK 98036/36:
LLK 98058:
LLK 98058/58:
Intensive sun radiation in areas of high ambient temperatures may cause inadmissible temperature rise inside of
the luminaire. This may result a decrease in lifetime of the electronic ballast (EVG). Therefore those luminaires
should be switched off during daytime by a photocell control.
(1)
The tests of clamping ranges and torque values were performed with metal mandrel. The clamping range can
vary by using cables with different manufacturing tolerances and material properties. Please use the
combination of sealing 1 + 2 for the intermediate region.
(2)
When selecting the seal rubber, ensure that the cap nut can be tightened when carrying out any future
maintenance work on the cable entry.
3.

Conformity with standards

This light fitting has been designed, manufactured and tested according to the state of the art and
to DIN EN ISO 9001:2008 and EN ISO/IEC 80079-34:2011.
The apparatus are conform to the standards specified in the EC-Declaration of conformity, enclosed
separately.
2 x 18 W
1 x 36 W
2 x 36 W
1 x 58 W
2 x 58 W
IEC 60081-2220
IEC 60081-2420
IEC 60081-2122
I
IP66
-20 °C ... +40 °C
-20 °C ... +40 °C
single-wire
multi-wire
1.5 mm²
1.5 mm²
6.0 mm²
4.0 mm²
2 x 2.5 mm
2
2.5 mm² for max. 16 A
M25 x 1.5
Ø cable
Nm
10.0
2.3
13.0
2.6
13.5
1.5
15.0
2.3
3.0 Nm
M20 x 1.5 thread
approx. 4.0 kg
approx. 6.0 kg
approx. 6.0 kg
approx. 7 .3 kg
approx. 7 .3 kg