Fault
E509: Malfunction hot sensor. All red
LEDs light up.
E510: Malfunction ambient sensor. All
red LEDs light up.
E511: Malfunction cold sensor 1. All
red LEDs light up.
E512: Malfunction cold sensor 2. All
red LEDs light up.
E513: Malfunction cooling 1 defective.
All red LEDs light up.
E514: Malfunction cooling 2 defective.
All red LEDs light up.
E515: Malfunction cooling 1. All red
LEDs light up.
E516: Malfunction cooling 2. All red
LEDs light up.
E600: Malfunction communication
button. All red LEDs light up.
E601: Malfunction communication Ad-
vanced Card. All red LEDs light up.
E602: Malfunction communication Ba-
sic Card. All red LEDs light up.
E603: Malfunction electronics temper-
ature. All red LEDs light up.

Warranty

The warranty conditions issued by our relevant sales
company apply in all countries. We shall remedy possi-
ble malfunctions on your appliance within the warranty
period free of cost, provided that a material or manufac-
turing defect is the cause. In a warranty case, please
contact your dealer (with the purchase receipt) or the
next authorised customer service site.
(See overleaf for the address)

Technical data

Device performance data
Working voltage of the battery
Power frequency
Power protection (slow-blowing)
Max. power input
Water supply pressure
Water supply temperature
Pressure adjustment range for
CO
2
Ambient temperature
Water dispenser, max.
Min. temperature of chilled water
Cooling capacity of chilled water
Dimensions and weights
Width
Depth
Height
Height with stand
Weight
Weight with stand
Sound pressure level L
pA
Cup for cup dispenser in stand (option)
Cup collar diameter
Hy Protect filter
max. permissible medium temper-
ature
max. permissible medium pres-
sure
max. flow performance
typical filter capacity
Filter life
Cause
The hot water sensor is defective.
The unchilled water sensor is defective.
The sensor in the cooling module is defective.
The sensor of the additional cooler in the stand is de-
fective.
The cooling module is defective.
The additional cooler in the stand is defective.
The temperature in the cooling module is too low (The
cooling module is frozen).
The temperature in the additional cooler in the stand is
too low (the cooling module is frozen).
The control panel of the device control is faulty.
The Advanced card of the device control is faulty.
The basic card of the device control is faulty.
The temperature of the device control is too high.
Active Pure filter
max. permissible medium temper-
ature
max. permissible medium pres-
sure
max. flow performance
max. capacity
Filter life
WPD 200
Advanced
Subject to technical modifications.
V
220-240
All parts/components containing water are suited and
approved for the use in direct contact with drinking wa-
Hz
50
ter in accordance with current industry standards.
A
10
The device has been certified for food suitability by the
Fresenius Institute and meets the requirements of the
W
1900
Mineral and Table Water Ordinance.
MPa
0,15 -0,6
(bar)
(1,5-6)
°C
4-35
MPa
0,30...0,35
(bar)
(3,0...3,5)
°C
5 - 35
l/h
120
°C
4
l/h
40
mm
390
mm
520
mm
450
mm
1450
kg
35
kg
50
dB(A) <43
mm
70...71
°C
+80
MPa
0,6(6)
(bar)
l/h
120
l
20000
Years 2
Rectification
1. Set the power switch to "0".
2. Call the Service.
1. Set the power switch to "0".
2. Call the Service.
1. Set the power switch to "0".
2. Call the Service.
1. Set the power switch to "0".
2. Call the Service.
1. Set the power switch to "0".
2. Call the Service.
1. Set the power switch to "0".
2. Call the Service.
1. Set the power switch to "0".
2. Call the Service.
1. Set the power switch to "0".
2. Call the Service.
1. Set the power switch to "0".
2. Wait 1 minute.
3. Set the power switch to "1".
4. If this happens again, call the Service.
1. Set the power switch to "0".
2. Wait 1 minute.
3. Set the power switch to "1".
4. If this happens again, call the Service.
1. Set the power switch to "0".
2. Wait 1 minute.
3. Set the power switch to "1".
4. If this happens again, call the Service.
1. Set the power switch to "0".
2. Wait 1 minute.
3. Set the power switch to "1".
4. If this happens again, call the Service.
WPD 200
Advanced
°C
+35
MPa
0,6(6)
(bar)
l/h
120
l
10000
Years 1
Material / Approvals
English
25

Quicklinks ausblenden: