3. Insert the SD card into the SD card slot with the cor-
rect side facing you.
Note
The SD card must be formatted in the FAT32 file sys-
tem.
4. Close the device door.
5. Insert the drip tray.
Display
>SD card<
>Slide show on< >YES< or >NO< select
(display flashes)
When selecting >NO< back to >SD card<
When selecting >YES<: >Start delay<
set minutes (display flashes)
>Selected minutes<
>Display duration xx s< (display flashes) Plus / Minus
>Selected display duration<
>Slide show parameters<
>Load parameters<
Load settings? >YES< or >NO< select
(display flashes)
When selecting >NO< back to >Load pa-
rameters<
When selecting >YES<: Data from the
SD card is saved on the device, then
back to >Load parameters<
>Save parameters<
>Save parameters?< >YES< or >NO<
select (display flashes)
When selecting >NO< back to >Save pa-
rameters<
When selecting >YES<: Data from the
device is saved on the SD card, then
back to >Save parameters<
>Save parameters<
>Updating the firmware<
> >YES< or >NO< select (display flash-
es)
When selecting >NO< back to >Updating
the firmware<
When selecting >YES<: Data from the
SD card is saved on the device, then go
back to >Updating the firmware<
>Finish<
Note
Updating the firmware takes a maximum of 5 minutes.
Do not switch off the device while updating the firmware.
The device cannot be operated while the firmware is be-
ing updated.
If the SD card does not contain firmware, the"Updating
the firmware option is not displayed.
The firmware and the programme "SD Card Manag-
er", which is required for transferring to the SD card,
can be obtained from Kärcher Customer Service.
Maintenance
Sanitisation
The automatic sanitisation starts automatically at the
programmed time, see Chapter "User menu/Operating
parameters/Sanitisation data".
Sanitisation and rinsing are carried out automatically.
Extraordinary thermal sanitisation is required after a re-
pair or after a shut down of more than 8 days and must
be started manually.
1. Empty the can before and after sanitisation (see
Chapter "Care and maintenance/empty can (op-
tion)").
Display
>Start rinsing!<
>Rinse in progress XX:XX min
>Rinse interrupted, continue!<
2. Empty the container and place it under the water
outlet again.
Display
>Rinse interrupted, continue!<
>Rinse in progress XX:XX min
Note
During sanitisation, the device produces a slightly high-
er operating noise.
Manually start the filter change
The manual start of an extraordinary filter change takes
place after a longer shutdown (see Chapter Removing
and installing the filter).
Manually start the initial Start-Up
The manual start of an initial Start-Up is carried out after
a longer shutdown or extensive repairs (see Chapter In-
itial Start-Up menu).
Button
Enter
If sampling is to be carried out, samples must be taken
Plus / Minus
immediately after sanitisation has been completed, in
compliance with the rules for microbiological water anal-
ysis, and evaluated by an accredited laboratory.
Removing and installing the filter
Plus / Minus
WARNING
Enter
Health risk
Improper work can result in harmful germs getting into
the device.
Enter
Pay attention to hygiene and cleanliness when chang-
ing the filter cartridge.
Minus
Wear sterile disposable gloves when changing the filter.
Enter
If a filter change is necessary, the symbol "I" (Info) is
Enter
shown in the display.
The request to change the filter is made after the filter
life has expired or if the filter is clogged.
The due filter change can be started in the user menu.
The menu guides the user through the filter change.
For an extraordinary filter change, carry out the fol-
lowing steps:
1. Remove the drip tray and open the device door.
Enter
2. Press the "Menu" button.
3. Close the device door.
Enter
4. Insert the drip tray.
5. Place a container under the water outlet.
Display
>User menu<
>Maintenance<
Minus
>Filter change<
Enter
>Change filter? NO<
Enter
Select >YES<
>Can under the dispenser?<
>Pressure reduction 30 s<
The pressure in the system is relieved.
6. Empty the container.
7. Remove the drip tray.
Back
8. Open the device door.
9. Turn the filter to the left until the tab is visible.
Illustration N
Support
1
Tab
2
Filter
3
Handle
4
a Remove the filter
b Inserting the filter
10. Pull the filter downwards out of the holder and re-
move it.
Note
The used filter can be disposed of as household waste
after the water has been poured off.
11. Put on sterile gloves.
12. Unpack the new filter.
13. Turn the new filter so that the handle is on the left
side.
14. Insert the filter from below into the corresponding
holder.
15. Turn the filter to the right as far as it will go.
16. Check the installation position: The markings on the
Button
label and on the filter must be aligned.
Illustration O
Enter
Back (X)
Support
1
Filter
2
Note
The filters must be fitted to match the labelling on the
Button
holder and must not be interchanged.
17. Close the device door.
Enter
18. Insert the drip tray.
19. Place a container under the water outlet.
Sampling
Button
Enter
Plus
Enter
Plus
Enter
Plus/Minus
Enter
Enter
English
Display
>Active Pure filter change carried out?<
or >Hy Protect filter change carried out?<
Display >YES< or >NO< flashes
changed filter
>Can under the dispenser?<
>Rinse in progress XX l<
Note
During rinsing, the container must be emptied several
times.
Display
>Rinse in progress XX l<
>Rinse interrupted, continue!<
20. Empty the container.
21. Place the container under the water outlet.
Display
>Rinse interrupted, continue!<
>Rinse in progress XX l<
>Rinse in progress 00 l<
>Filter change<
Finish
Note
It is recommended to perform an extraordinary sanitisa-
tion after the rinsing.
Emptying the drip tray
As soon as the drip tray has reached its maximum fill
level, the message"Empty the drip tray appears in the
display.
1. Remove the drip tray.
2. Empty the drip tray.
3. Check the drip tray for contamination, clean if nec-
essary.
4. Insert the drip tray again.
The device is now ready for operation.
The display shows the selection of water types.
Note
If the drip tray is not inserted correctly, the mes-
sage"Empty the drip tray is also displayed.
Emptying the can (optional attachment kit)
As soon as the can reaches its maximum fill level, the
message "Empty the drain can" appears in the display.
1. Open the door on the stand.
2. Unscrew the closing lid.
Illustration P
Connection of drain hose for drip tray
1
Cable of fill level sensor for can
2
Connection of drain hose for rinsing valve
3
Closing lid with fill level sensor
4
Can
5
3. Remove the closing lid with the fill level sensor.
4. Remove the can from the stand.
5. Empty the can.
6. Insert the can into the stand.
7. Put on the closing lid with the fill level sensor and
tighten it.
8. Close the door on the stand.
Display
>Can empty?<
The device is now ready for operation.
The display shows the selection of water types.
Daily rinsing
This function must be activated by the customer service
or by telephone support.
● When this function is activated, the device performs
a short rinse of the dispensing area every day.
● This automatic rinse starts 2 minutes before the set
start time for thermal sanitisation.
Button
Minus
Enter
Enter
Button
Back (X)
Button
Enter
Back (X)
Button
Enter