Herunterladen Inhalt Inhalt Diese Seite drucken

Filter Change; Troubleshooting; Troubleshooting Schedule - Husqvarna S 13 Bedienungsanweisung

Vorschau ausblenden Andere Handbücher für S 13:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

All equipment once used must be regarded as
contaminated and be treated thereafter.
All parts that are contaminated after service work
must be disposed in a correct procedure in plastic
bags. Refer to local regulations.
Use correct personal equipment when you clean the
Personal protective equipment on
product. Refer to
page 6 .
Clean the external surface with a moist cloth.
Clean the filters and the dust extractor in applicable
area.
Vacuum the pre-filter from the inside. Always use
dust extractors with HEPA filter and a soft brush to
not damage the filter.
Do not use water on electrical components.
Do not clean the dust extractor with high pressure
(air or water).
Do not put tools on the surface of the filter, it can
cause damage to the filter.
Do not make a hole in the HEPA filter, it can cause a
health risk.

Filter change

WARNING:
equipment, refer to
equipment on page 6 , during filter change.
Dust can come out during filter change.
WARNING:
switch in the Off position and disconnect the
cord from the wall outlet during filter change.
WARNING:
fasteners can cause damage to the operator
when assemble the product.

Troubleshooting schedule

Issue
Motor does not start
Motor stops immediately after
starting
10
Use personal safety
Personal protective
Always turn the motor
Be careful, the toggle

Troubleshooting

Cause
No power
Cable defective
Switch defective
Soft start defective
Wrong fuse
Shortcut in cable/machine
To change the HEPA filter
CAUTION:
Trying to clean a HEPA filter will destroy it.
When installing the replacement filter, make
sure to not touch the inside of the filter. Any
kind of force/damage on the inside of filter
media will destroy the new filter.
Note:
Recommended intervals for filter change: Pre-
filter every 6 months and HEPA filters every 12 months.
1. Loosen the screws on the filter cover cap.
2. Carefully lift the filter into a clean plastic bag, this
bag must be properly disposed.
3. Insert a new filter in reverse order.
To change the pre-filter
CAUTION:
filter in order to clean it, use only low
pressure water from the inside through to
the out. Hitting the filter with force, high
pressure water or use of compressed air will
destroy the filter. The filter must be 100%
dry before returning into the housing.
1. Loosen the 3 toggle fastners and remove the top.
2. Take the bag from the new filter.
3. Lift out the filter and place it gently in a plastic bag.
This bag must be properly disposed.
4. Insert a new filter.
Do not clean HEPA filters.
When you remove the pre-
Solution
Plug in machine
Replace cable
Replace switch
Replace soft start
Connect to correct fuse
Order service
896 - 005 - 01.12.2022