Technical errors
In general, please check whether the following faults can be remedied by thorough cleaning before contacting technical support.
Error CODE
Left Counting
Error left counting sensor
Middle Counting
Error middle counting sensor
Right Counting
Error right counting sensor
Banknote receiving
1. Error Banknote Receiving
sensor
2. Error Circuit Main Board
Rotate speed
1. Error with Main Motor
sensor
2. Broken transport belt
3. Error with Rotate Speed
4. Error Circuit Board
Banknote feeding
1. Feeding Sensor Error
sensor
2. Error Circuit Board
UVL sensor
Error left UV sensor
UVR sensor
Error right UV sensor
CIS Board error
Error on the CIS board
Back drawer open
Back of the machine open
JAM! Remove all
Banknote jam in the machine
the notes and press
"RESET"
P a g e
| 11
Information
Sensor
Sensor
1. Replacing the sensor if cleaning is not successful
2. Check wiring between sensors and mainboard Replace
mainboard
1. Replacing the sensor if cleaning is not successful
2. Check wiring between sensors and mainboard Replace
mainboard
1. Replacing the sensor if cleaning is not successful
2. Check wiring between sensors and mainboard Replace
mainboard
1. When starting the machine, the sensor is covered by
banknotes or foreign objects.
2. Replacing the sensor if cleaning is not successful
3. Check wiring between sensors and mainboard Replace
mainboard
1. Replacing the main motor or the main board
2. Exchange of the transport belt
3. Replacing the sensor if cleaning is not successful
4. Replacement of the circuit board
1. Replacing the sensor if cleaning is not successful
1. Testing the wiring
2. Replacing the sensor if cleaning is not successful
1. Testing the wiring
2. Replacing the sensor if cleaning is not successful
1. Testing the wiring
2. Replacement of the sensors / the board if cleaning is not
successful.
Close the rear flap
Remove all banknotes and start the counting process again.
Solution