Approval marks
DEKRA 16ATEX 0045 X and / or IECEx DEK 16.0021X and / or DEKRA 21UKEX0211X
UL - E-file number: E223122
Permissible ambient temperature during operation for devices with Ex marking
All operating positions
Protection against foreign objects and water
When mounted
Specific conditions of use (for ATEX)
The Industrial PC SIMATIC IPC477E PRO including the top side of the stand provides a degree of protection of at least IP65. The
bottom side of the stand shall be connected to a certified enclosure, providing a degree of protection of at least IP54
according to EN 60079-7 for gas and non-conductive dust and IP6X according to EN 60079-31, for conductive dust, taking
into account the environmental conditions under which the equipment is used.
The equipment shall be installed in such a way that the risk of mechanical danger is low.
To avoid an electrostatic charge, wipe the enclosure surface with a damp cloth only.
When used in an area requiring the use of equipment with EPL Gc:
the equipment shall only be used in an area of not more than pollution degree 2, as defined in EN 60664-1.
Provisions shall be made to prevent the rated voltage from being exceeded by transient disturbances of more than 119 V.
Specific conditions of use (for IECEx)
The Industrial PC SIMATIC IPC477E PRO including the top side of the stand provides a degree of protection of at least IP65. The
bottom side of the stand shall be connected to a certified enclosure, providing a degree of protection of at least IP54
according to IEC 60079-7 for gas and non-conductive dust and IP6X according to IEC 60079-31, for conductive dust, taking
into account the environmental conditions under which the equipment is used.
The equipment shall be installed in such a way that the risk of mechanical danger is low.
To avoid an electrostatic charge, wipe the enclosure surface with a damp cloth only.
When used in an area requiring the use of equipment with EPL Gc:
the equipment shall only be used in an area of not more than pollution degree 2, as defined in IEC 60664-1.
Provisions shall be made to prevent the rated voltage from being exceeded by transient disturbances of more than 119 V.
Specific conditions of use (for CCCEx)
The Industrial PC SIMATIC IPC477E PRO including the top side of the stand provides a degree of protection of at least IP65. The
bottom side of the stand shall be connected to a certified enclosure, providing a degree of protection of at least IP54
according to GB/T 3836.1 for gas and non-conductive dust and IP6X according to GB/T 3836.1 and GB/T 3836.31, for
conductive dust, taking into account the environmental conditions under which the equipment is used.
The equipment shall be installed in such a way that the risk of mechanical danger is low.
To avoid an electrostatic charge, wipe the enclosure surface with a damp cloth only.
When used in an area requiring the use of equipment with EPL Gc:
The equipment shall only be used in an area of not more than pollution degree 2, as defined in GB/T 16935.1.
Provisions shall be made to prevent the rated voltage from being exceeded by transient disturbances of more than 119 V.
Observe the following FAQ regarding the use of an HMI / IPC device in hazardous areas: ATEX-FAQ
(https://support.industry.siemens.com/cs/ww/en/view/291285)
WARNING
The device has to be used in pollution degree 2 environment only.
WARNING
Use copper supply wires of at least 0,75 mm
CAUTION
DC-Version
If a main circuit breaker for DC-supply should be installed in hazardous locations as described above it has to be intended for
use in that area. Otherwise it must be installed in an area which is known to be non-hazardous.
WARNING
Opening the device
DO NOT OPEN WHEN ENERGIZED.
6
With CFast or SSD
IP65
or AWG 18.
2
+0 to +35 °C
Enclosure Type 4X/12