Herunterladen Inhalt Inhalt Diese Seite drucken

Trouble-Shooting And Service - clage CFX-U Gebrauchsanleitung

Elektronischer durchlauferhitzer
Vorschau ausblenden Andere Handbücher für CFX-U:
Inhaltsverzeichnis

Werbung

GB
6
Repairs must only be carried out by
authorised professionals.
If a fault in your appliance cannot be
rectified with the aid of this table,
please contact the service organis-
tion of your importer or the Central
Customer Service Department at
CLAGE. Please have the details of
the typeplate at hand.
CLAGE GmbH
Central Customer Service
Pirolweg 1–5
21337 Lüneburg
Tel.: (+49) 4131 89 01-40
Fax: (+49) 4131 89 01-41
E-Mail: service@clage.de
CFX-U-GA-10_Sprachen-02-2010.indd 13

Trouble-shooting and service

Your instantaneous water heater CFX-U was manufactured conscientiously and checked
several times before delivery. Should malfunctions nevertheless occur, it is usually only
due to a bagatelle. First attempt to switch the house fuses off and on again in order to
reset the electronics. Next, try to remedy the problem with reference to the following
table. In doing so, you will avoid unnecessary expense of customer service assistance.
Problem
Water stays cold
Display flashes error message
"Er"
Flow rate of hot water too
weak
Selected temperature is not
reached , "MAX" lights
Selected temp. is not
reached , "MAX" does not
light
Symbol "sun" flashes
Appliance heats, the display
does not light
Remote control display: value
is incorrect
Symbol "battery" lights
Display: "no" and appliance
does not response to the
remote control
Display:"no" and radio
symbol flashes
Display: " - -" and radio
symbol flashes
13
Cause
Solution
Master fuse tripped
Renew or activate fuse
Reset STDB by customer
STDB tripped
service
Switch fuse off and on. If
Control system has
"Er" still flashes contact
switched off
customer service
Outlet fitting dirty or
Clean shower head, jet
calcified
regulator or sieves
Fine filter dirty or
Let clean fine filter by a
calcified
specialist
Water flow rate too
Reduce water flow rate at
high
the tap
Cold water has been
Tap hot water only; set
added via the tap
temperature for use
Inlet temperature
exceeding nominal
Reduce inlet temperature
temperature
No radio contact
Press key and repeat login
Flat batteries
Replace batteries
Standby mode of the
Press a key on the remote
remote control
control
Insert two new type AAA
Flat batteries
batteries
Place the remote control
Range exceeded
closer to the appliance,
register again
Range of the radio
Disturbance through other
signal exceeded
radio emitters
Hold the remote control in
Registration in process
front of the water heater
24.02.2010 16:24:32 Uhr

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis