Wiring for the Input/Output functions
Inputs/outputs can be managed from the local configurator. The factory settings are below:
• input IN1: if the 230 V is available
• input IN2: if the 230 V is available
• output OUT1: if charging is in progress
• Input 1/Input 2
Use scenario:
- 50% load reduction for load shedding function,
- vehicle charges during off-peak hours (according to tariff subscription),
- charge optimisation related to the start-up of an energy production source (photovoltaic, cogeneration).
C1
C2
1
2
• Output 1
Use scenario:
- 50% load reduction information output,
- output triggering an indicator light or ambient lighting to indicate charging in progress,
- information that charging is in progress via an energy production source (example: cogeneration/Combined Heat & Power).
Output:
- 0 V to 30 V
/ 10 mA to 500 mA
- 0 V to 250 V
/ 10 mA to 500 mA
C2
1
2
1 Supplier electronic meter
2 Subscriber circuit breaker/supplier entry point
3 2 A protection circuit breaker
unauthorised load / 0 A load shedding,
50% load reduction,
the relay is closed.
230 V
1
N
N
2A
N
3
N
N
2A
N
3
1
2
2
IN1
IN2
Contactor
IN1
IN2
OUT
A1
1
A2
2
24 V
230 V
OUT
31