Herunterladen Inhalt Inhalt Diese Seite drucken

Viatom Checkme Lite Benutzerhandbuch Seite 18

Vorschau ausblenden Andere Handbücher für Checkme Lite:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 36
Radiated RF
3 V/m 80
IEC61000-4-3
MHz to
2.5 GHz
Note 1: At 80 MHz to 800 MHz, the separation distance for the higher frequency range applies.
Note 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected
by absorption and reflection from structures, objects and people.
Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless)
a
telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast
cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due
to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured
field strength in the location in which the device is used exceeds the applicable RF compliance
level above, the device should be observed to verify normal operation. If abnormal performance
is observed, additional measures may be necessary, such as re-orienting or relocating the device.
Over frequency range 150kHz to 80MHz. For Resp field strength should be less than 1V/m.
b
Recommended separation distances between portable and mobile RF communications
equipment and thedevice
The Health Monitor is intended for use in an electromagnetic environment in which radiated RF
disturbances are controlled. The customer or the user of the Health Monitor can help prevent
electromagnetic interference by maintaining a minimum distance between portable and mobile
RF communications equipment (transmitters) and the monitor as recommended below,
according to the maximum output power of the communications equipment.
Rated
max.
output power of
transmitter(W)
0.01
0.1
3 V/m 80 MHz
to
2.5 GHz
Separation distance according to frequency of the transmitter (m)
150 kHz - 80 MHz
d 1 .2 P
0.12
0.38
Recommended separation distances:
80 MHz~800 MHz:
800MHz-2.5GHz:
Where, P is the maximum output power
rating of the transmitter in watts(W)
according to the transmitter
manufacturer and d is the
recommended separation distance in
meters (m).
Field strengths from fixed RF
transmitters, as determined by an
electromagnetic site survey
less than the compliance level in each
frequency range
Interference may occur in the vicinity of
equipment marked with the following
symbol:
80
MHz
-
MHz d 1 .2
P
0.12
0.38
17
d 1 .2
P
d 2 .3 P
, shouldbe
a
.
b
800
800 MHz
-
GHz
d 2 .3
P
0.23
0.73
2.5