Herunterladen Inhalt Inhalt Diese Seite drucken

Additional Functions - SICK WLA12L Betriebsanleitung

Klein-lichtschranken
Vorschau ausblenden Andere Handbücher für WLA12L:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
6.3
Setting
6.4

Additional functions

8027709/2022-04-12 | SICK
Subject to change without notice
Sensing range adjustment
WLA12Lx-xxxxxx3xAxx with teach-in button:
The sensitivity and operating reserve are optimized by pressing the teach-in button until
the yellow LED flashes (approx. 1-3 seconds). Lead an object into the path of the beam.
The yellow LED goes out, meaning the object is detected and the setting is correct.
1
1...3 sec.
2
Figure 14: WLA12Lx-xxxxxx3xAxx, adjusting the sensing range with teach-in button
NOTE
Do not operate the teach-in button using sharp objects.
Please refer to the enclosed "IO-Link photoelectric sensors" operating instructions for
information about adjusting the IO-Link sensing range.
IO-Link
The sensor can be used in standard I/O mode (SIO) or IO-Link mode (IOL). All auto‐
mation functions and other parameter settings are effective in IO-Link mode and in
standard I/O mode. Output of binary switching signals in standard I/O mode via pin
4 / black wire and via pin 2 / white wire.
Information on the IO-Link functions (IODD) can be found in the enclosed IO-Link
photoelectric sensor operating instructions or downloaded from
the device part number.
OPERATING INSTRUCTIONS
www.sick.com
O P E R A T I N G I N S T R U C T I O N S | WLA12L
en
under
35

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

W12

Inhaltsverzeichnis