Error code

If the screen displays an error code "Ex", please refer to the table below.
Code Situation Problem
E1
Not
heating
properly.
E3
Not
heating
properly.
E4
All
functions
do not
work,
buzzing
warn.
E5
All
functions
do not
work,
buzzing
warn.
E6
Not
heating
and
filtering
properly.
Buzzing
warns.
Causes
Wrong
Temperature
temperature
control sensor
control sensor.
short circuit or
open circuit.
High water
1. The filled
temperature
indicator.
2. The filter
Low water
The pool water is
temperature
lower than 2°C
indicator.
(36°F).
High water
The filled water is
temperature
over 50°C (122°F)
indicator.
Water pressure
is not big
enough to
activate
heating.
Solutions
Contact service center
1. Cut off the power, make
water is over
45°C (113°F)
cartridge was
put on the
wrong suction
2. Put the filter cartridge
fitting (higher
suction fitting).
Inlet or outlet
on inner wall
are blocked.
Filter cartridge
is too dirty.
Pool water
does not reach
minimum
water level.
Do not release
air from pump
sure the pool water is
between 2°C~44°C
(36°F~111°F). If this does
not solve the problem,
refer to the box below.
on the lower suction
fitting.
Cut off the power, make
sure the pool. water is
between 2°C~44°C
(36°F~111°F)
If this does not solve the
problem, refer to the
box below
Cut off the power, turn
to qualified electrician to
reset the thermal cutout
described in next
paragraph.
If this does not solve the
problem, refer to the
box below
Clean inlet and outlet
Clean or replace filer
cartridge
Add water to reach
water level
Do air release as
outlined again
If this does not solve the
problem, refer to the
box below