Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Specifications - Supra PACCO Installations- Und Bedienungshandbuch

Vorschau ausblenden Andere Handbücher für PACCO:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 32
You have just purchased a wood burning stove from our range. We would first like to congratutate you on your choice. This app liance
has been carefully designed. In order to make the most of all its advantages, we would advise you to request the services of one of our
specialists. This will ensure that the installation is made in accordance with good practices and will guarantee the best operating and
safety conditions, bearing all the responsibility for the final installation.
Before lighting the fire for the first time, please read these installation instructions and user manual carefully. Retain th e manual and
warranty (which indicates the model and serial No.). The person performing the installation work shall be fully responsible for any failure
to comply with the instructions set out in these documents.
Your stove has a "good draw" but you do not know its draught value. The chimney draught is measured in Pascal (Pa). The
inserts, fireboxes and stoves have been designed, optimised and manufactured in accordance with standards NF EN 13229 (or
NF EN 13240) to operate connected to a chimney with a draught of 12 Pa. It frequently happens (in more than one in two
chimneys) that the draught is far too high (over 20 Pa) due to the fact that the chimney is either too high or due to the flu e
liner. In this case, the appliances will operate in abnormal conditions which may lead to:
- Excessive wood consumption: this can be three times as much as an appliance with a draught of 12 Pa.
- A fire that "does not last" and burns too quickly while producing insufficient heat.
- A quick and inevitable deterioration of the appliance (cracks in the cast iron panels or in the refractory bricks)
- A voided warranty.
To avoid all these problems, there is only one solution!
Get a professional to check the chimney draught (with the appliance operating) and, if it is above 20 Pa, then install a damper
or an adaptor at the flue connection.

1. TECHNICAL SPECIFICATIONS

SWIVEL STOVE
Stove category
Rated heat output (1)
Operating mode
Connection type
Mean flue gas temperature
Efficiency
Seasonal efficiency
CO concentration (13 % 02)
CO2 concentration (13 % 02)
Dust concentration (13 % 02)
COV
NOX
Fuel
Log size
Nominal load per hour approx.
Refuelling
Prohibited fuels
Approx. flue gas mass flow
Fluepipe nominal diameter
Flue pipe specifications
Minimum dimensions of the chimney terminal
Ø mín flue lining or insulated metal duct
Minimum height of the pipe above the
appliance
Ventilation of the room
Draught (10 Pa = 1 mm CE)
Nominal efficiency
Performance in slumber mode (min. permitted)
Max. permitted
Nameplate
Accessorires supplied
Grippers; Insulating glove
Option available
AT15 Draught adaptor
(1) Rated power in operation with the door closed, wood or lignite fuel, according to the tests performed under standard EN 1 3240.
(2) DTU 24.1 covering flue ducting, DTU 24.2 covering chimneys equipped with a closed stove; NIF EN 13240 covering solid fuel burning
stoves. (Available at AFNOR).
- IMPORTANT -
- IMPORTANT ASSEMBLY INSTRUCTIONS -
PACCO / P. HAUT / P. SUR PIED / P.
BÛCHER
Intermittent
10 kW
Only with the door closed
Vertical
314 °C
78 %
68 %
0.10 %
10.37 %
3
18 mg/Nm
.
99 mg/Nm3
105 mg/Nm3
Wood
50 cm.
2.9 kg
45 min.
All the rest, including coal and its
derivatives
7.2 g/sec
150 mm.
20 x 20 cm
150 mm.
4 m.
1.2 dm²
12 Pa ± 2 Pa
6 Pa ± 1 Pa
20 Pa
On the rear of the appliance