7. The heater has an overheat protection that turns the device off if any parts become
extremely hot.
8. If the temperature sensor is not functioning as it should,
display. In such instances, the heater will switch itself off. Please contact your
distributor or importer.
9. To turn off the heater, press the ON/OFF button. Should the heater be left unused
for a longer period of time, pull out the plug.

Temperature calibration

SG2000LED/SG2000LED BLACK/SG2000GLASS
See figure 6 on separate illustration sheet
It may occur deviation between the temperature registered by the heater and the actual
temperature in the room. This can be caused by several reasons, however, the most
comon is that the heater is placed in a fair distance from where you usually reside. When
you set the temperature to for example 22 degrees, it is only natural that you expect the
same temperature where your sofa is placed for instance. However, the temperature
sensor is placed on the product itself, and therefore a deviation in temperature may occur.
To adjust this, all Mill heaters are equipped with a calibration function, which enables you
to adjust the temperature registered by the heater. N.B! The room must have achieved a
stable temperature before any calibration.
Press and hold
in the room. Confirm with

Resetting the heater

See figure 7 on separate illustration sheet
Turn off the heater's main switch. Press and hold
heater's main switch.
@
for 5 seconds and use + or – to set the actual temperature observed
@
or wait 15 seconds for automatic confirmation.
$
will be shown on the
@
%
or
while you turn on the