Herunterladen Inhalt Inhalt Diese Seite drucken

Hilti Nuron SD 5000-22 Original Bedienungsanleitung Seite 30

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
▶ Do not send batteries through the mail. Consult your shipper for instructions on how to ship undamaged
batteries.
▶ Prior to each use and before and after prolonged transport, check the product and the batteries for
damage.
Storage
WARNING
Accidental damage caused by defective or leaking batteries !
▶ Always store your products with the batteries removed!
▶ Store the product and the batteries in a cool and dry place. Comply with the temperature limits stated in
the technical data.
▶ Do not store batteries on the charger. Always remove the battery from the charger when the charging
operation has completed.
▶ Never leave batteries in direct sunlight, on sources of heat, or behind glass.
▶ Store the product and batteries where they cannot be accessed by children or unauthorized persons.
▶ Prior to each use and before and after prolonged storage, check the product and the batteries for
damage.
9
Troubleshooting
If a problem occurs, always observe the charge-status and fault indicator of the battery. See the section
headed Status indicators of the Li­ion battery.
If the trouble you are experiencing is not listed in this table or you are unable to remedy the problem by
yourself, please contact Hilti Service.
Trouble or fault
Product does not work.
Screw is not completely off-
set and tool stops.
The control switch can't be
pressed, i.e. the switch is
locked.
The product runs but the
screw cannot be turned.
Running speed suddenly
drops considerably.
The battery runs down more
quickly than usual.
The battery doesn't engage
with an audible click.
Product or battery gets very
hot.
10
Disposal
WARNING
Risk of injury due to incorrect disposal! Health hazards due to escaping gases or liquids.
▶ DO NOT send batteries through the mail!
▶ Cover the terminals with a non-conductive material (such as electrical tape) to prevent short circuiting.
▶ Dispose of your battery out of the reach of children.
▶ Dispose of the battery at your Hilti Store, or consult your local governmental garbage disposal or public
health and safety resources for disposal instructions.
24
English
Possible cause
Low battery.
The battery is not fully inserted.
The depth gauge is set incorrectly.
The switch-on interlock is acti-
vated.
The wrong direction of rotation is
set.
Low battery.
Battery state of health not optimal
The retaining lug on the battery is
dirty.
Electrical fault
Action to be taken
▶ Charge the battery. → page 21
▶ Insert the battery. → page 21
▶ Adjust the depth gauge.
▶ Set the forward/reverse switch
to forward or reverse rotation,
as applicable. → page 22
▶ Use the forward/reverse switch
to set the correct direction of
rotation. → page 22
▶ Charge the battery. → page 21
▶ Call up the battery's state of
health. → page 19
▶ Replace the battery, if neces-
sary.
▶ Clean the retaining lug and push
the battery in until it engages.
▶ Switch the product off immedi-
ately, remove the battery and
contact Hilti Service.
2293284
*2293284*