Application and safety precautions
•
Warning: UV-C emitted from this product. Avoid eye and skin exposure to unshielded product. Follow installation instructions and user
manual.
•
Warning: these UV-C products are not meant to be used in applications or activities which may cause and/or lead to death, personal injury
and/or damage to the environment.
Warning: Products not designed and/or intended to be used to disinfect medical devices or for medical purposes; Signify excludes any and
•
all liability for any such improper use.
•
This UV-C product is intended to be used for the disinfection of Indoor air.
•
The back cover must be closed properly before disinfection, otherwise the UVC lamp will not work.
•
There should be no light leakage at the air inlet on the side of the body. If there is, please check whether the carbon cloth is installed
correctly.
•
Contact manufacturer or its maintenance department and other similar professionals for repair.
•
If the power cord is damaged, it must be replaced with a dedicated cord or with a dedicated component purchased from its manufacturer
or maintenance department.
•
Lamps include Mercury. If a lamp breaks, ventilate the room for 30 minutes and remove the parts, preferably with gloves. Put them in a
sealed plastic bag and take it to your local waste facilities for recycling. Do not use a vacuum cleaner. Please follow User Manual.
•
UVC Exposed luminaire parts (other than metal parts), like Lamp holder, end cap etc. might change color after a certain period of usage due
to the UV-C light property.
•
UV-C light emitted from UVC lamp is much "stronger" than normal sunlight and can cause a severe sunburn-like reaction to your skin, and
similarly, could damage the retina of your eye, if exposed.
This appliance is not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities, or lack of
•
experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible
for their safety.
Children should be supervised to ensure that they do not play with the appliance.
•
Lamp/Ballast/Shading cloth replacement
1. Only those who have received instruction training can replace the relevant parts. C ontact Signify dealer or the designated after-sales
service.
2. Turn off the power supply and unplug product before changing the lamp or connection! Ensure to put on gloves when installing the device
or replacing the lamp.
*Use only Philips brand TUV lamps. TUV lamp type: 927903004007 TUV PL-L 18W/4P 1CT/25; TUV lamp lifetime: 9000h
Visible marking on product:
UVC lamp error code
The UVC light will be on after power on, the UV working light will be kept on. When the lamp is damaged, the UV indicator flashes, and the display area is showing
the following error code:
error
code
Damaged
First digit
lamp
1
1pc lamp
2
damaged
3
4
12
13
2pcs lamp
14
damaged
23
24
34
123
124
3pcs lamp
damaged
134
234
4pcs lamp
damaged
1234
Shading cloth error code
Error code will be displayed after the accumulated working time of the product reaches 9000 hours. The product cannot be started. At this time, the shading cloth
must be replaced.
error
code
First digit
E
replace shading cloth
Digital display
Second digit
Third digit
E
NA
1
E
NA
2
E
NA
3
E
NA
4
E
1
2
E
1
3
E
1
4
E
2
3
E
2
4
E
3
4
E
NA
6
E
NA
7
E
NA
8
E
NA
9
E
8
8
Digital display
Second digit
Third digit
7
7
For example, the panel displays
"E8", indicating that the lamps
1, 3 and 4 are broken. The tube
indicator code is at the base of
the UV lamp holder.
* Display will show the error code when max. 3pcs lamps are failure for UVCA200
or max. Meanwhile the product can keep at working status with error code display.
The display will show the timing for 10secs after pressing timer button, then come
back to error code display mode.
If all the lamps are damaged, the product cannot start with dedicated error code
display.