Herunterladen Inhalt Inhalt Diese Seite drucken

Werbung

OPTOIO-PCIe32
STANDARD
EDP No.: A-840600
32 optocoupler isolated digital inputs
32 optocoupler isolated digital outputs
wasco
®
user's guide

Werbung

Inhaltsverzeichnis
loading

Inhaltszusammenfassung für Wasco OPTOIO-PCIe32 STANDARD

  • Seite 1 OPTOIO-PCIe32 STANDARD EDP No.: A-840600 32 optocoupler isolated digital inputs 32 optocoupler isolated digital outputs wasco ® user‘s guide...
  • Seite 2 ® © Copyright 2015 by Messcomp Datentechnik GmbH This documentation is copyright by Messcomp Datentechnik GmbH. All rights are reserved. Messcomp Datentechnik GmbH reserves the right to modify the products described in this manual at any time and without preannouncement.
  • Seite 3: Inhaltsverzeichnis

    8.1 Installation of the Windows driver ...............19 development files ............19 ® 8.2 Installation of the Windows ® 8.3 Programming of the OPTOIO-PCIe32 by wasco driver ........22 8.4 Access to the board OPTOIO-PCIe32 ............23 Standard 8.5 Assignment of the Memory Mapped I/O addresses ..........23 8.6 Compatibility to OPTOIO-PCI32...
  • Seite 4 Programming ..............25 ® 9.1 Installing the Linux driver ..................25 9.2 Supported Linux Distributions/Kernelversions ............25 ® 9.3 Programming the OPTOIO-PCIe32 with wasco driver ........25 9.4 Access to the OPTOIO-PCIe32 ..............26 Standard 9.5 Assignment of the Memory Mapped I/O addresses ..........26 10. Accessories ..................27 10.1 Compatible wasco...
  • Seite 5: Description

    ® 1. Description The wasco ® interface card OPTOIO-PCIe32 provides 32 digital STANDARD inputs and 32 digital outputs with galvanic isolation, individually for each channel. Optocouplers of high quality ensure the potential separation for the inputs and outputs. All input optocouplers are bipolar. Special high power output optocouplers can handle a maximum switching current of up to 150 mA.
  • Seite 6: Installation Of The Optoio-Pcie32

    ® 2. Installation of the OPTOIO-PCIe32 STANDARD 2.1 How to install the card into your system Before you insert the card unplug the power cord or make sure, there is no current to/in the computer. Inserting into a running system may cause...
  • Seite 7: Connectors

    ® 3. Connectors 3.1 Position of the connector plugs CN1: Optocoupler Outputs OUT00...OUT31 CN2: Optocoupler Inputs IN00...IN31 OPTOIO-PCIe32 © 2015 by Messcomp Datentechnik GmbH EV08 STANDARD...
  • Seite 8: Pin Assignment Of Cn1

    ® 3.2 Pin assignment of CN1 OUT31- OUT31+ OUT30- OUT30+ OUT29- OUT29+ OUT28- OUT28+ OUT27- OUT27+ OUT26- OUT26+ OUT25- OUT25+ OUT24- OUT24+ OUT23- OUT23+ OUT22- OUT22+ OUT21- OUT21+ OUT20- OUT20+ OUT19- OUT19+ OUT18- OUT18+ OUT17- OUT17+ OUT16- OUT16+ OUT15-...
  • Seite 9: Pin Assignment Of Cn2

    ® 3.3 Pin assignment of CN2 IN31- IN31+ IN30- IN30+ IN29- IN29+ IN28- IN28+ IN27- IN27+ IN26- IN26+ IN25- IN25+ IN24- IN24+ IN23- IN23+ IN22- IN22+ IN21- IN21+ IN20- IN20+ IN19- IN19+ IN18- IN18+ IN17- IN17+ IN16- IN16+ IN15-...
  • Seite 10: System Components

    ® 4. System Components 4.1 Block diagram +12V +12V Control Logic PCIe Bus Interface OPTOIO-PCIe32 © 2015 by Messcomp Datentechnik GmbH EV08 STANDARD...
  • Seite 11: Access To The System Components

    The relevant addresses for OPTOIO-PCIe32 depend on the base address given by the BIOS. You can access to the OPTOIO-PCIe32 by double-word access only. For reasons of compatibility the wasco drivers process or take into account the two least significant bytes only.
  • Seite 12: Optocoupler Isolated Digital Inputs

    ® 5. 32 Optocoupler Isolated Digital Inputs Die OPTOIO-PCIe32 provides 32 input channels which are opti- STANDARD cally isolated by optocouplers. 5.1 Pin assignment of the input optocouplers 16,14,12,10 15,13,11,9 1,3,5,7 2,4,6,8 OPTOIO-PCIe32 © 2015 by Messcomp Datentechnik GmbH...
  • Seite 13: Input Voltage Ranges

    ® 5.2 Input voltage ranges You can select two different input voltage ranges for each optocoupler input by setting jumpers on JP3, JP4, JP5 and JP6 JP5 JP6 OPTOIO-PCIe32 © 2015 by Messcomp Datentechnik GmbH EV08 STANDARD...
  • Seite 14 ® Following table shows the data of the two input voltage ranges: Jumper high 0...1 V 5...15 V 0...2 V 14...30 V IN16 IN24 IN00 IN08 IN17 IN25 IN01 IN09 IN02 IN10 IN18 IN26 IN03 IN11 IN19 IN27 IN20...
  • Seite 15: Input Circuitry

    ® 5.3 Input circuitry Jumper Optocoupler IN.. + Protection Diode IN.. - 5.4 Input current - 1,1V ≈ (Jumper off) 3400Ω - 1,1V ≈ (Jumper on) 1000Ω OPTOIO-PCIe32 © 2015 by Messcomp Datentechnik GmbH EV08 STANDARD...
  • Seite 16: Optically Isolated Outputs

    ® 6. 32 Optically Isolated Outputs Die OPTOIO-PCIe32 provides 32 output channels, which are optically isolated by optocouplers. 6.1 Pin assignment of the output optocouplers 6.2 Optocoupler specifications Voltage collector-emitter: max. 50V Voltage emitter-collector: 0,1V Current collector-emitter: 150 mA 6.3 Output circuitry...
  • Seite 17: Board Configuration

    ® 7. Board Configuration 7.1 Board Identification The board Identification enables you to dif- Jumper ferentiate between several PC boards of the same type in your system. This is realised by a software readable jumper block. The board identification to be read consists of one Byte (16 Bit) and is...
  • Seite 18: Access With 16 Or 32 Bit

    ® 7.2 Access with 16 or 32 Bit The jumper block JP1/1-2 enables you to set the data width of the access. If the jumper block JP1/1-2 is not set (Default) the card works in compati- bility mode. In this mode the card is accessed in 16-bit mode. Additionally,...
  • Seite 19: Windows Programming

    ® ® 8. Windows Programming ® 8.1 Installation of the Windows driver ®, To apply the card under Windows a special driver has to be installed, which enables access to the card. ® After starting-up Windows 10, 8 und 7 your operating system automati- cally registers a new hardware device to be found.
  • Seite 20 ® Having installed driver software and development files completely, your system control panel shows an icon for the localisation of all wasco ® and PCIe cards existing in the system. OPTOIO-PCIe32 © 2015 by Messcomp Datentechnik GmbH EV08 STANDARD...
  • Seite 21 ® ® Start the card‘s monitoring by double-clicking the "wasco " icon. Follow- ing screen appears (in this example an OPTOIO-PCIe16 may be STANDARD used) Once the system detected the card, this window shows card name, board ID, I/O address and possible interrupt number for each card. Furthermore the „Information“...
  • Seite 22: Programming Of The Optoio-Pcie32 By Wasco

    After having installed Kithara‘s development files by means of the setup program the folder wasco contains of the relevant development files and program examples. More program examples specified for access to the OPTOIO-PCIe32 you can find on the enclosed CD or please visit our Website.
  • Seite 23: Access To The Board Optoio-Pcie32

    ® 8.4 Access to the board OPTOIO-PCIe32 Standard The access to the OPTOIO-PCIe32 is done exclusively via the board Standard name (type of card) OPTOIO-PCIe32/standard. 8.5 Assignment of the Memory Mapped I/O addresses The Memory Mapped I/O addresses of the single hardware components...
  • Seite 24: Compatibility To Optoio-Pci32

    ® 8.6 Compatibility to OPTOIO-PCI32 STANDARD Developing the OPTOIO-PCIe32 and the corresponding driver, STANDARD special care was taken to use an access as identical as possible to the OPTOIO-PCI32 . This enables you to switch from PCI to PCIe in STANDARD existing programs in a very easy way.
  • Seite 25: Linux Programming

    ® ® 9. Linux Programming , you can find a Linux wasco ® ® To use the board with Linux driver on the supplied CD or on our website. This is available in code form and can therefore be changed and adapted by the customer at any time.
  • Seite 26: Access To The Optoio-Pcie32

    ® 9.4 Access to the OPTOIO-PCIe32 Standard The access to the OPTOIO-PCIe32 is done exclusively via the board Standard name (type of card) OPTOIO-PCIe32standard. 9.5 Assignment of the Memory Mapped I/O addresses The Memory Mapped I/O addresses of the single hardware components...
  • Seite 27: Accessories

    ® 10. Accessories 10.1 Compatible wasco ® accessories Connecting parts EDP No. PDB68F33DS68 Ribbon cable A-498600 KMDB-68 Connecting Board A-494800 DS68R100DS68 Connecting wire (1 meter) A-492200 DS68R200DS68 Connecting wire (2 meters) A-492400 DS68R500DS68 Connecting wire (5 meters) A-492800 10.2 Connecting technique (application examples) DS68R ...*...
  • Seite 28: Single Components For Own Assembly

    ® 10.3 Single components for own assembly Connection parts EDP No. SCSI-II plug 68pin for flat ribbon cable A-553200 SCSI-II jack 68pin for flat ribbon cable A-557200 Slot bracket with cutout for connector male/female A-577800 68 pin flat ribbon cable 68pin...
  • Seite 29: Troubleshooting

    Please check all settings of your computer or contact your system administrator. (Since these are BIOS settings, we cannot expand on this issue. We refer to your system manual) Did you install the latest driver version of the wasco ® drivers? Updates you can find here: http://www.messcomp.com...
  • Seite 30: Specifications

    ® 12. Specifications Optocoupler Inputs Optocoupler: LTV-244 or compatible 32 channels, optically isolated Galvanic isolation even between every single channel with each two separate connectors Overvoltage protection by protection diodes Two different input voltage ranges selectable by jumpers: Range 1 high = 14..30 Volt...
  • Seite 31: Product Liability Act

    ® 13. Product Liability Act Information about Product Liability The Product Liability Act (Act on Liability for Defective Products - Prod- HaftG) in Germany regulates the manufacturer‘s liability for damages caused by defective products. The obligation to pay compensation can be given, if the product’s pres-...
  • Seite 32 ® * unplug the power plug before you open a device or make sure, that there is no current to/in the device. * You only may start up any components, boards or devices, if they have been installed in a secure touch-protected casing before. During installa- tion they must be de-energized.
  • Seite 33: Ec Declaration Of Conformity

    ® 14. EC Declaration of Conformity It is hereby confirmed, that the following CE marked product OPTOIO-PCIe32 STANDARD EDP Number A-840600 complies with the requirements of the relevant EMC directives 2014/30/ EU. This declaration will lose its validity, if the instructions given in this manual for the intended use of the products are not fully complied with.
  • Seite 34 ® Reference system for intended use This PC expansion card is a not independently operable device. CE conformity only can be assessed when using additional computer components simultaneously. Therefore the CE conformity only can be confirmed when using the following reference system for the intended...

Diese Anleitung auch für:

A-840600

Inhaltsverzeichnis