Handling the device
3.6

Undervoltage supervision

The supervision of an undervoltage condition is done
with two thresholds. It will be activated after 250ms
and everytime the output is switched on.
In case the output voltage is below the 1st under-
voltage threshold
(„UV
has been switched on, the display will indicate a
warning
. The warning remains in the display
until acknowledged by the button
vents unseen errors. The warning is removed if no
error is persistent anymore and after it has been
acknowledged.
The 2nd undervoltage threshold
generate an alarm if the output voltage falls below
and switch off the output. This is indicated by
and on the „ERROR" pin of the analog interface.
The output can be switched on again, after the alarm
has been acknowledged.
PSI880-40R, PSI880-60R
Profile
1
Name
0..80V
U adj max
80.00V
14.40V
U adj min
0.00V
9.60V
U output
88.00V
12.00V
I output
0.. Inom 0.. Inom 0.. Inom 0.. Inom 0.. Inom
OVP
88.00V
13.20V
UV warning
0.00V
0.00V
UV alarm
0.00V
0.00V
PSI8360-10R, PSI8360-15R
Profile
1
Name
0..360V
U adj max
360.00V
28.80V
U adj min
0.00V
19.20V
U output
0.00V
24,00V
I output
0.. Inom 0.. Inom 0.. Inom 0.. Inom 0.. Inom 0.. Inom
OVP
396.00V
26.40V
UV warning
0.00V
0.00V
UV alarm
0.00V
0.00V
Instruction Manual
PSI 800 R Series
warning") after the output
. This pre-
(„UV
shutdown") will
Voltage ranges
2
3
4
12V
24V
36V
28.80V
43.20V
57.60V
19.20V
28.80V
38.40V
24.00V
36.00V
48.00V
26.40V
39.60V
52.80V
0.00V
0.00V
0.00V
0.00V
0.00V
0.00V
Voltage ranges
2
3
4
24V
48V
60V
57.60V
72.00V 132.00V 264.00V
38.40V
48.00V
88.00V 176.00V
48.00V
60.00V 110.00V 220.00V
52.80V
66.00V 121.00V 242.00V
0.00V
0.00V
0.00V
0.00V
3.7

Configurable voltage profiles

The device feature several voltage profiles that
are pre-configured for common applications. See
tables below. The topmost profile allows to set volt-
age and current within the full nominal values, i.e.
from 0...100%. The other profile are configurable,
but within a limited voltage range. See the tables
below. In all profiles there is also a set value for the
OVP threshold and both undervoltage thresholds.
The profile depend on the nominal output voltage
of the device.
3.8

Control locations

Control locations are places from where the device
is accessed. With this series, there are several
control locations which are indicated by status texts
in the display:
• local
- is manually activated by the user with but-
ton
. In this situation the device can not be
controlled remotely. This can be useful to intercept
during a permanent remote control and adjust
some settings on the device. After enabling remote
control again by leaving
remote control is not activated automatically.
• remote
- the unit is remotely controlled by one of
the digital interface cards and manual access is
not possible. Pressing button
local
and aborts remote.
• extern
- the unit is remotely controlled by the in-
ternal analog interface and manual access is not
possible. Pressing button
5
and aborts extern.
48V
5
6
110V
220V
0.00V
0.00V
0.00V
0.00V
not editable
local
with button
changes to
changes to