1.
Switch off the vacuum cleaner and disconnect the plug from the mains. To do this
always pull on the plug and not on the cable.
2.
Open the exhaust air grill (H) (this is at the rear of the cyclone vacuum cleaner.)
3.
The exhaust air filter is visible when the grill has been opened.
4.
Rinse the filter under cold running water and allow to dry.
Caution!
Only ever clean the filter with clean water and do not use soap or detergent.
These would destroy the filter.
5.
Put the exhaust air filter back into place (or replace with a new one) and place in the
grill.
6.
Close the exhaust air filter grill.
NOTE: After a certain number of cleanings the filters will be damaged or impossible to get back
in their initial shape. In such case, please contact the nearest customer service to obtain new
filters.
Cleaning the dust collector
1.
Switch off the vacuum cleaner and disconnect the plug from the mains. To do this
always pull on the plug and not on the cable.
2.
You can press the lock button of the dust container together with the out of their
anchoring with the aid of the carrier handle on the dust container. Now lift out the dust
container and carry it to the waste bin.
3.
A push button is located on the dust container that you can use to open and empty it
automatically (bottom-down technology). To do this hold the dust container over your
dustbin and press on the empty button.
4.
Clean the inside of the dust collector and the lid with the multi-cyclone filter with a
damp cloth or sponge, but make sure they are totally dry before using the appliance
again.
5.
Close the lid. Put the dust collector back in the appliance until it locks in place.
Cleaning the HEPA filter
The HEPA filter and the HEPA cover should be cleaned regularly. Cleaning is best done when
emptying the dust container. To do this follow the instructions in the Emptying dust container
section.
1.
Switch off the vacuum cleaner and disconnect the plug from the mains. To do this
always pull on the plug and not on the cable.
2.
Now lift out the dust container.
3.
Turn the dust container cover carefully (J) until it is released and the HEPA filter will
come away easily (K).
4.
Now rinse the HEPA filter under running water and allow it to dry (L).
Caution! Only ever clean the filter with clean water and do not use soap or detergent.
These would destroy the filter.
5.
Place the HEPA filter back in the HEPA cover (or replace with a new one) and fit it into
the dust container. Then fit the dust container back into position in the cyclone dust
container until it snaps into place. Your cyclone vacuum cleaner is now ready for use
again.
Motor protection valve
The unit has the protection valve, when the dust cup is full of dust, HEPA filter is blocked or the
air path is blocked, the protection valve will turn on automatically avoiding motor over-heat in
order to prolong the life of motor.
Cleaning the other parts of the vacuum cleaner
The casing, dust collecting chamber and filter chambers of the vacuum cleaner can be wiped
with a damp cloth if required. No liquid must enter the vacuum cleaner in the process. Never
Copies of the I/B. Please reproduce them without any
changes
except
under
International BELGIUM. The pages must be reproduced and
folded in order to obtain a booklet A5 (+/- 148.5 mm width x
210 mm height). When folding, make sure you keep the good
numbering when you turn the pages of the I/B. Don't change
the page numbering. Keep the language integrity.