• After starting the data transfer, the operating display shows a green light, preceded by
a confirmation tone for 30 s. After conclusion of the data transfer, the operating display
shows a red light.
Programming in the Master Device:
Function
Operation/Programming
Initiate programming
* - master code - # (default master code: 123456)
Transfer starten
98 - #
Finish programming
*
9. Connection of Two Systems (Lock)
For an increased safety of access/egress, e.g. in banks, prisons, laboratories, etc., two
systems can be connected so that they lock each other. This is also known as interlock.
Programming:
Step 1: First, read all authorised users into one device and then transfer the data, as described
in „Passing on of User Data," to the second device.
Step 2: Set both devices to „interlock active."
Function
Operation/Programming
Initiate programming
* - master code - # (default master code: 123456)
interlock inactive
90 - # (default setting)
or
interlock active
91 - #
Finish programming
*
10. Technical Data
Number of users:.........1000 (100 fingerprints, 888 cards/PINs, 2 panic codes, 10 visitors)
Fingerprint reader:..............................................................................................capacitive
PIN:.................................................................................................................4 to 6 digits
RFID reader:..................................EM (125 kHz), MiFare (13,56 MHz), coverage 2 to 6 cm
Relay output:....................................................................changer (NO/COM/NO), max. 2 A
Relay active time:................................................................ 0 to 99 s (default setting: 5 s)
Inside calliper (exit button):..................................................................switching to ground
Sabotage alarm:...........................................................................................optical sensor
Power supply:............................................................................................12 to 28 V
Power consumption:.................................................standby: 60 mA, active: max. 150 mA
Surrounding conditions:.....................................................-30 °C to +60 °C, 0 to 98 % rh
Protection class:..........................................................................................................IP66
Dimensions (W x H x D):........................................................................68 x 145 x 25 mm
Weight:.....................................................................................................................500 g
11. Declaration of Conformity
The dnt Innovation GmbH, Maiburger Straße 29, 26789 Leer, Germany, herewith declares
that the device
"fingerprint code lock BioAccess PRO"
is in compliance with the essential requirements and the other relevant provisions of Directive
2014/30/EU. The declaration of conformity can be found at the following address: www.dnt.de
12. Disposal
This device may not be disposed of with domestic waste!
According to the directive concerning electronic devices and electronic
old devices, they are to be disposed of at the local collection centres for
electronic old devices!
13. Contact
Do you have any questions regarding the product or its operation?
Our Technical Customer Service would be pleased to provide you with comprehensive
and qualified information.
E-Mail: info@dnt.de
1. German edition 11/2021
Documentation © 2021 dnt Innovation GmbH
All rights reserved. Without the publisher's written consent, this user manual may not be
reproduced or copied in any way, whether in full or in part. It is possible that the user
manual at hand still contains printing faults or errors. Nevertheless, the information given
in this user manual is regularly reviewed for correctness, and any corrections will be made
in the next edition. We do not assume liability for technical or typographical mistakes as
well as their consequences. All trademarks and property rights are recognised. Changes in
accordance with technical advances can be carried out without prior notice.
DNT000013-11/2021, version 1.0
Importer: dnt Innovation GmbH
Maiburger Straße 29 · 26789 Leer · Germany · www.dnt.de
AC/DC