MAINTENANCE AND CLEANING
C LE AN I N G O R R E PL AC I N G TH E BAS KET FI LTE R
In the case of the floor-standing model, the basket filter must be cleaned by a skilled person.
1. Disconnect the power plug.
2. Close the ball valve underneath the toilet ceramic
appliance.
3. Remove the reinforced braided hose by hand and
drain the residual water into a receptacle.
1
2
24
All manuals and user guides at all-guides.com
4. Remove the basket filter.
5. Clean and descale the basket filter.
6. Insert the cleaned basket filter.
7. Screw on the reinforced braided hose.
2
1
8. Open the ball valve underneath the toilet ceramic
appliance.

MALFUNCTIONS DURING OPERATION

E LECTR I CAL S H O C K ! FATAL DAN G E R !
Never open the unit in order to repair it yourself. Never modify the device or add an any additional modules. The AXENT shower toilet
carries live parts and opening it exposes those present to fatal danger ! Warranty and liability claims as a result of wrong handling are
specifically excluded.
Malfunction
Cause
No Function
The unit is in stand-by-mode
Main plug is not connected
Defective fuse on electrical
distributor
Fuse in internal mains connection is
defective
Power supply is interrupted
No water spray (5 times
No water supply
«beep»)
Shower temperature too low
Shower temperature is set too low
Shower spray is too weak or
Spray intensity is set too low
no water is spraying out at
Spray nozzle clogged or
all
blocked with lime-scale
Basket filter is clogged or
blocked with lime-scale
Spray arm does not move
Power supply is interrupted
out
No water supply
Night light doesn't work
Night light is in OFF mode
Night light cannot turn off
Night light is in ON mode
Continuous «beep»
Shower toilet is defective
Control knob does not work,
Contamination on hinges
ambient light flickers or does
not light up

Fault clearance

Slightly knock the toilet lid
Connect the main plug
Replace fuse on electrical distributor
Disconnect the main plug and contact customer
service
Have the power supply checked by a skilled person
Ensure the water supply is released
Increase shower temperature
Increase spray intensity
Run decalcification program
Clean or replace the basket filter
Contact customer service for floor-standing model
Restore the power supply
Ensure that the water supply is released
Switch night light into ON or AUTO mode
Switch night light into AUTO or OFF mode
Disconnect the main plug and contact customer
service
Cleaning the hinges toilet seat and cover with a
moistened cloth